Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2010.tde-08082011-104737
Documento
Autor
Nombre completo
Elaine Wirney Martins
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2010
Director
Tribunal
Potiens, Maria da Penha Albuquerque (Presidente)
Costa, Alessandro Martins da
Rodrigues, Letícia Lucente Campos
Título en portugués
Estudo e determinação de fatores de influência das dimensões dos frascos de radiofármacos utilizados no IPEN para calibração de ativímetros
Palabras clave en portugués
ativímetros
calibração
controle de qualidade
medicina nuclear
Resumen en portugués
A eficiência e a segurança de uma prática de medicina nuclear dependem, entre outros fatores, de um programa de controle de qualidade, principalmente no que diz respeito à utilização de medidores de atividade de radionuclídeos (ativímetros). Dentre as maiores fontes de erro nas medidas realizadas com um ativímetro estão: a espessura, o tamanho e o volume do frasco que contém o radiofármaco, considerando que um ativímetro típico tem a sua resposta reconhecidamente dependente do frasco utilizado. O propósito desse trabalho foi implantar um programa de controle de qualidade além de estabelecer fatores de correção referente à geometria do frasco de vidro para distribuição de radiofármacos e calibração de ativímetros, considerando que o Laboratório de Calibração de Instrumentos (LCI) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) possui um Sistema Padrão Secundário NPL-CRC radionuclide calibrator, fabricado pela Southern Scientific, composto por uma câmara de ionização tipo poço e um sistema de medida de corrente, com rastreabilidade ao National Physical Laboratory (NPL) e calibrado com um frasco de vidro tipo P6 que possui dimensões diferentes dos utilizados pelo IPEN. Foram testados os radiofármacos 67Ga, 131I, 201Tl e 99mTc, todos produzidos pelo IPEN. Os resultados demonstraram uma variação de até 22% para o radiofármaco 201Tl, sendo que a menor variação foi encontrada para o 131I (2,98%). Os fatores de correção encontrados devem ser incorporados na calibração rotineira dos ativímetros.
Título en inglés
Study and determination of the influence factors of the radiopharmaceutical vials dimensions used for activimeter calibration at IPEN
Palabras clave en inglés
activimeter
calibration
nuclear medicine
quality control
Resumen en inglés
The efficiency and safety of the nuclear medicine practice depend, among others factors, of a quality control programme, mainly related to the use of the nuclide activity meters (activimeter). One of the most important sources of errors in the activimeter measurements is the thickness, size and volume of the vial that contains the radiopharmaceutical considering that a typical activimeter has its response dependent of the vial used. The objective of this work was to establish a quality control programme and the correction factors for the geometry of the vials used for distribution of radiopharmaceutical and activimeters calibration, considering that the Calibration Laboratory of Instrumentos (LCI) of the Instituto de Pesquisas Energéticas e Nucleares (IPEN) has a NPL-CRC Secondary Standard Radionuclide Calibrator System, manufactured for the Southern Scientific plc, compound by an ionization chamber well type and a current measurement system, with traceability to National Physical Laboratory (NPL) and calibrated with a P6 vial type with different dimensions of the one used for the IPEN. The radiopharmaceutical produced by IPEN 67Ga, 131I, 201Tl and 99mTc, had been tested using the two different vials. The results shown a maximum variation of 22% for 201Tl, and the minimum variation was 2.98% for 131I. The correction factors must be incorporated in the routine calibration of the activimeters.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
2010MartinsEstudo.pdf (1.61 Mbytes)
Fecha de Publicación
2011-08-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.