• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.85.2020.tde-07102020-084657
Document
Auteur
Nom complet
Roberto Simplício Guimarães
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2020
Directeur
Jury
Genezini, Frederico Antonio (Président)
Arenhardt, Valeria
Rodrigues, Cleber Lima
Titre en portugais
Desenvolvimento de um instrumento de movimentação e troca de amostras de radioisótopos para detectores HPGe - Germânio Hiper-Puro
Mots-clés en portugais
Arduino
baixo custo
detector HPGe
mecanismo
precisão
Resumé en portugais
Um conjunto mecânico comandado por um microcontrolador que movimenta e posiciona com precisão uma série de amostras irradiadas foi montado. Este conjunto é personalizado para um arranjo com um detector de HPGe e blindagem,e traz ganhos dentre os quais se destacam desobrigar a presença do operador durante a aquisição de dados, minimizando sua exposição às radiações oriundas da amostra e proporcionar medidas com repetibilidade. O arranjo onde o equipamento foi montado é localizado no laboratório de ativação neutrônica na CRPq no IPEN/CNEN. Esse mecanismo, controlado por uma placa denominada Arduino MEGA 2560, possui uma interface amigável desenvolvida em C#, interage com o sistema de aquisição denominado Genie2000 e armazena os dados da contagem em um banco de dados MySQL. Em todo o conjunto mecânico existem peças desenvolvidas e manufaturadas em impressora 3D. Nesse arranjo o conjunto das amostras fica posicionado na lateral externa da blindagem, sendo necessária blindagem adicional em torno do conjunto para evitar aumento da radiação de fundo no laboratório e que a radiação emitida por elas alcance o detector. A amostra aproxima-se do detector por uma escotilha superior que abre e fecha conforme a movimentação do braço mecânico que contem a amostra na sua extremidade. Sensores de fim de curso asseguram a calibração do sistema em todos os seus movimentos, sendo que a amostra pode ser posicionada em frações de mm em relação ao detector HPGe, conforme programado pelo usuário , utilizando todo o curso do interior da blindagem.O instrumento pode ser replicado e customizado para outros sistemas de detecção na espectrometria gama, mantendo a filosofia de utilizar matérias acessíveis e ter o custo menor que os sistemas comerciais.Testes de repetitibilidade foram executados demonstrando assim a eficiência do sistema.
Titre en anglais
Development of a radioisotope sample movement and exchange instrument for HPGe - Hyper-Pure Germanium detectors
Mots-clés en anglais
Arduino
engine
HPGe detector
low cost
precision
Resumé en anglais
A micro controller driven mechanical assembly that accurately moves and positions a series of irradiated samples to HPGe detectors to minimize user exposure to gamma radiation from the sample and provide long-term repeatability measurements. The purpose of this work was to develop a custom mechanism for the arrangement called Canberra 6, located in the neutral activation laboratory at CRPq at IPEN / CNEN. This mechanism controlled by a board called Arduino MEGA 2560, has a user-friendly interface developed in C# that interacts with the acquisition system called Genie2000 and stores counting data in a MySQL database. Throughout the mechanical assembly there are unique parts developed. and manufactured in 3D printer. In this arrangement the sample set is positioned on the outside of the HPGe detector shield, and additional shielding around the assembly is required. The sample approaches the detector through an upper hatch that opens and closes as the mechanical arm that contains the sample at its end moves. Limit sensors ensure the system is calibrated in all its movements, and the sample can be positioned in fractions of mm to the HPGe detector as programmed by the user using the full stroke inside the shield. be replicated and customized for other detection systems in gamma spectrometry, maintaining its low cost and efficiency, including for other equipment installed in the referred IPEN laboratory.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2020-10-15
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.