• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.85.2012.tde-05112012-161632
Documento
Autor
Nombre completo
Karoline Cianci Gishitomi
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2012
Director
Tribunal
Koskinas, Marina Fallone (Presidente)
Maidana, Nora Lia
Pecequilo, Brigitte Roxana Soreanu
Título en portugués
Determinação da taxa de desintegração e das probabilidades de emissão gama por decaimento do I-123
Palabras clave en portugués
coincidência
HPGe
I-123
Monte Carlo
padronização
Resumen en portugués
Neste trabalho foi desenvolvido o método de padronização do 123I em sistema de coincidências 4π(X,A)-γ. O 123I foi produzido no cíclotron Cyclone-30 do IPEN CNEN/SP, por meio da irradiação do 124Xe. O 123I decai com uma meia vida de 13,22 horas pelo processo de captura eletrônica seguido da emissão de radiação gama. Foi aplicada a técnica de extrapolação linear da eficiência para determinação da atividade e para determinação do coeficiente de conversão interna total do nível de 159 keV, obtido a partir da inclinação da curva de extrapolação. A curva de extrapolação experimental foi comparada com a simulação de Monte Carlo, executada pelo código ESQUEMA. As fontes radioativas foram também medidas em um sistema de espectrometria de HPGe, a fim de determinar a probabilidade de emissão gama por decaimento para várias transições gama. Todas as incertezas envolvidas e suas correlações foram analisadas aplicando a metodologia de matriz de covariância e os parâmetros medidos foram comparados com os da literatura.
Título en inglés
Disintegration rate and gamma ray emission probability per decay measurement of 123I
Palabras clave en inglés
coincidence
HPGe
I-123
Monte Carlo
standardization
Resumen en inglés
This paper describes the development of the 123I standardization method in a 4π(X, A)-γ coincidence system. The 123I was produced in the ciclotron-30 of IPEN CNEN / SP through the irradiation of the 124Xe. The 123I decays with a half-life of 13.22 hours by electron capture process followed by emission of gamma radiation. The experimental extrapolation curve was determined and compared to Monte Carlo simulation, performed by code ESQUEMA. From the slope of the experimental curve, the total conversion coefficient for the 159 keV total gamma transition, 159, was determined. All radioactive sources were also measured in an HPGe spectrometry system, in order to determine the gamma-ray emission probability per decay for several gamma transitions. All uncertainties involved and their correlations were analyzed applying the covariance matrix methodology and the measured parameters were compared with those from the literature.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2012-11-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.