Título en portugués
Avaliação de câmaras monitoras em feixes padrões de radiologia a partir de simulações com o método de Monte Carlo
Palabras clave en portugués
câmaras monitoras
CSR
EGSnrc
espectros de raios X
IAEA/TRS-457
Resumen en portugués
Detectores de radiação que são utilizados em radiologia diagnóstica devem ser calibrados com feixes padrões de raios X. Durante as calibrações, estes feixes são monitorados a partir de câmaras monitoras, que podem ser do tipo de transmissão, ou podem realizar a monitoração pela penumbra do feixe de radiação. Neste trabalho foram realizadas simulações com o método de Monte Carlo, utilizando o código EGSnrc, para a avaliação de quatro câmaras monitoras: uma câmara monitora comercial de transmissão, uma câmara de ionização do tipo Baldwin-Farmer, e duas câmaras monitoras de modelo de transmissão e anelar desenvolvidas no IPEN. Inicialmente foi criado um sistema de raios X capaz de simular espectros de radiodiagnóstico convencional e mamografia com parâmetros de qualidades definidos na norma IAEA/TRS-457. Em seguida, a dependência energética de cada câmara monitora foi avaliada a partir de fatores de calibração em relação à câmara padrão de cada feixe simulado. Por fim, foi avaliada a dependência angular das câmaras monitoras de transmissão e anelar. Os espectros simulados foram comparados com referências internacionais e apresentaram as características esperadas pela teoria. Cada feixe padrão simulado apresentou os parâmetros de qualidade definidos na norma IAEA/TRS-457 utilizando a câmara monitora de transmissão de modelo comercial e a desenvolvida no IPEN. Os fatores de correção obtidos com as simulações foram comparados com resultados experimentais e mostraram baixa dependência energética da câmara monitora de transmissão desenvolvida no IPEN, e alta dependência energética da câmara monitora de modelo anelar, quando comparadas ao modelo comercial de transmissão. As câmaras monitoras desenvolvidas no IPEN apresentaram dependência angular de acordo com as normas internacionais.
Título en inglés
Evaluation of monitor chambers in standard beams of radiology and mammography with simulations using the Monte Carlo method
Palabras clave en inglés
EGSnrc
HVL
IAEA/TRS-457
monitor chambers
X-ray spectra
Resumen en inglés
Radiation detectors used in diagnostic radiology should be calibrated in standard X-ray beams. During calibrations, those beams are monitored by monitor chambers, using either transmission models or other ionization chambers that are able to monitor the beam in its penumbra. In this work an evaluation of four monitor chambers was performed: a transmission-type commercial monitor chamber, a Baldwin-Farmer ionization chamber, and two monitor chambers developed at IPEN in transmission and ring-shaped models; using the Monte Carlo method with the EGSnrc code. Initially, an X-ray system able to produce standard spectra of conventional diagnostic radiology and mammography beams with quality parameters described in IAEA/TRS-457 was created. Then, the energy dependence of each monitor chamber was evaluated by the calibration factors using the standard ionization chamber of each simulated beam. At the end, the angular dependence of the transmission and the ring-shaped monitor chambers was evaluated. The simulated X-ray spectra were compared to international references, and they presented the expected characteristics. Each simulated X-ray beam presented standard quality parameters using the transmission-type monitor chambers, the commercial model or the model developed at IPEN. The correction factors obtained in the simulations were compared to experimental results, and they presented a small energy dependence in the transmission-type monitor chamber developed at IPEN and a high energy dependence in the ring-shaped monitor chamber, when compared to the commercial transmission-type model. The monitor chambers developed at IPEN presented the angular dependence according to international regulations.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2022-06-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.