• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2006.tde-30072007-160907
Document
Auteur
Nom complet
Pedro Barco Cárnio
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2006
Directeur
Jury
Mazzer, Nilton (Président)
Camargo Filho, José Carlos Silva de
Maciel, Carlos Dias
 
Titre en portugais
Variação dos parâmetros físicos do campo ultra-sônico em fonoforese com diclofenaco gel
Mots-clés en portugais
Atenuação ultra-sônica
Fonoforese
Penetração de drogas transdérmicas
Transmissão ultra-sônica
Ultra-som
Resumé en portugais
O objetivo do presente trabalho foi de analisar, experimentalmente, a variação do índice de transmissão e o coeficiente de atenuação ultra-sônica no meio diclofenaco gel, bem como, a penetração do fármaco em amostras de gelatina semelhante a pele humana através da fonoforese. A variação destes parâmetros foi investigada em 120 amostras de agar-agar, (modo contínuo, 1 MHz de freqüência, nas intensidades de 1,0 e 1,5 W/'CM POT.2'), por 5 minutos. Os corpos de prova forma divididos em grupos referentes as intensidades de ultra-som utilizadas, e cada um destes grupos, foi subdividido em sub-grupos correspondendo aos diferentes meios utilizados para irradiação. A investigação da transmissão ultra-sônica foi medida a partir de um dosímetro de precisão ULTRASONIC POWER METER, modelo UPM-DT 10. O cálculo do coeficiente de atenuação foi realizado a partir dos dados de leitura da transmissão ultra-sônica. A penetração ou não da droga foi estudada por análise macroscópica e microscópica. Segundo os resultados obtidos não houve variação significativa nos índices de transmissão e nos coeficientes de atenuação do diclofenaco gel em comparação ao gel neutro. A penetração do medicamento foi de 3 mm para as amostras irradiadas com a intensidade de 1,0 W/'CM POT.2' e de 5 mm para as amostras irradiadas com 1,5 W/'CM POT.2', não houve evidência de penetração do fármaco no grupo controle. Os resultados obtidos neste estudo sugerem que a fonoforese do diclofenaco gel é efetiva nas intensidades 1,0 e 1,5 W/'CM POT.2'.
 
Titre en anglais
Variation of the physical parameters of the ultrasonic field in phonophoresis with diclofenaco gel
Mots-clés en anglais
Penetration of drugs
Phonophoresis
Therapeutic ultrasound
Transdermal drug delivery
Ultrasonic
Resumé en anglais
The objective of the present work was of analyzing, experimentally, the variation of the transmission index and the coefficient of ultrasonic reduction in the half diclofenaco gel, as well as, the penetration of the drug in samples of similar jelly the human skin through the phonophoresis. The variation of these parameters was investigated in 120 agar-agar samples, (continuous way, 1 MHz of frequency, in the intensities of 1,0 and 1,5 W/'CM POT.2'), for 5 minutes. The proof bodies form divided in referring groups the ultrasound intensities used, and each one of these groups, it was subdivided in sub-groups corresponding to the different means used for irradiation. The investigation of the ultrasonic transmission was measured starting from a ULTRASONIC POWER METER, model UPM-DT 10. The calculate it of the reduction coefficient was accomplished starting from the data of reading of the ultrasonic transmission. The penetration or not of the drug it was studied for it analyzes macroscopic and microscopic. According to the obtained results there was not significant variation in the transmission indexes and in the coefficients of reduction of the diclofenaco gel in comparison with the neutral gel. The penetration of the medicine went of 3 mm to the samples irradiated with the intensity of 1,0 W/'CM POT.2' and of 5 mm for the samples irradiated with 1,5 W/'CM POT.2', there was not evidences of penetration of the drug in the group control. The results obtained in this study suggest that the phonophoresis of the diclofenaco gel is effective in the intensities 1,0 and 1,5 W/'CM POT.2'.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2007-07-31
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs.
CeTI-SC/STI
© 2001-2024. Bibliothèque Numérique de Thèses et Mémoires de l'USP.