• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.82.2009.tde-29062010-112929
Documento
Autor
Nombre completo
Alessandro Márcio Hakme da Silva
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
Alves, José Marcos (Presidente)
Barbosa, Marcello Henrique Nogueira
Silva, Orivaldo Lopes da
Título en portugués
Análise morfométrica 2D e 3D de amostras de osso trabecular utilizando microtomografia tridimensional por raio-X
Palabras clave en portugués
Análise morfométrica 2D e 3D
Microtomografia tridimensional ('mü'CT)
Osso trabecular
Qualidade óssea
Tensor anisotropia
Resumen en portugués
Ossos trabeculares possuem uma microestrutura porosa e podem ser modelados como um sólido elástico linear, heterogêneo e anisotrópico. A microtomografia tridimensional por raios-x (uCT) tem sido mundialmente utilizada para a caracterização de osso trabecular em pesquisas relacionadas à qualidade óssea e à doenças do metabolismo ósseo como a osteoporose. Na literatura há poucas investigações comparando as análises morfométricas 2D e 3D de osso trabecular. Nesta investigação amostras de osso trabeculares cilíndricas extraídas da cabeça femoral bovina foram utilizadas para a comparação dessas análises por 'mü'CT. O software CT-Analyser foi utilizado para medidas em três direções (crânio-caudal, lateral-medial e anterior-posterior) de diversos parâmetros da microestrutura trabecular tais como espessura trabecular, separação trabecular, número trabecular e os autovalores do tensor de anisotropia (M). A comparação entre os valores dos parâmetros medidos por análises morfométricas 2D e 3D foi realizada pelo teste-t pareado com nível de significância p < 0,05 e por correlação linear de Pearson. Os autovalores da matriz M mostram que a microestrutura trabecular bovina tem uma tendência para a simetria transversalmente isotrópica. Os resultados obtidos mostram que a microtomografia tridimensional por raios-X é uma técnica de grande potencial para caracterização da qualidade óssea gerando bons parâmetros para o diagnóstico de doenças do metabolismo ósseo.
Título en inglés
2D and 3D morphometric analysis of trabecular bone using X-ray tridimensional microtomography ('mü'CT)
Palabras clave en inglés
2D and 3D morphometric analysis
3D X-ray microtomography ('mü'CT)
Bone quality
Fabric tensor
Trabecular bone
Resumen en inglés
Trebecular bones have a porous microstructure and can be modeled as a linear elastic solid, heterogenous and anisotropic. The x-ray tridimensional microtomography ('mü'CT) has been worldwide used for the assessment of trabecular bone in investigations related to bone quality and aimed to the diagnostic of bone metabolic diseases such as osteoporosis. In the literature few investigations have compared the 2D and 3D morphometric analysis of trabecular bone. In this investigation cylindrical trabecular bone samples were harvested from bovine head femur to carry out that comparison by 'mü'CT. The CT-Analyser software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) several microstructural trabecular parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). The comparison between the parameters values measured by 2D and 3D morphometric analysis was performed by the paired-sample t test with a level of significance p < 0,05 and the Pearson's linear correlation. The eigenvalues show that the bovine trabecular microstructure has a tendence to transverse isotropy symmetry. The results show that x-ray tridimensional microtomography ('mü'CT) is a technique of great potential for characterization of generating good bone quality parameters for the diagnosis of diseases of bone metabolism.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-09-02
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.