Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.82.2003.tde-22042004-100959
Document
Auteur
Nom complet
Carlos Alberto Marinheiro
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2002
Directeur
Jury
Picado, Celso Herminio Ferraz (Président)
Louzada, Mario Jefferson Quirino
Shimano, Antonio Carlos
Titre en portugais
Desenvolvimento de máquina de movimentos cíclicos para testes biomecânicos
Mots-clés en portugais
biomaterial
ensaio biomecânico
fadiga
movimento cíclico
Resumé en portugais
O ser humano locomove-se utilizando-se do complexo sistema neuro-músculo-esquelético, o que lhe confere qualidade de vida. Partes do sistema esquelético são passíveis de tratamento ou mesmo de substituição pelo emprego de materiais estranhos ao corpo humano mas que provocam pequena reação biológica e necessitam ser dimensionados de modo a suportar toda tensão resultante do movimento humano. O objetivo deste trabalho foi desenvolver uma máquina de ensaio cíclico para testes biomecânicos, de implantes utilizados nas cirurgias de reconstrução ósteo-articular, utilizando tecnologia nacional. A máquina possui um sistema de acionamento por meio de um motor trifásico de 2 HP, 1800 rpm; um sistema de transmissão de cargas cíclicas utilizando um eixo excêntrico, que aciona um pistão, que promove o movimento de duas alavancas que transmitem a carga para os componentes a serem ensaiados. Há um inversor de freqüência para controle do número de ciclos do motor, um reservatório de soro fisiológico com um sistema que mantém o soro aquecido entre 36 e 38 ºC, e uma bomba hidráulica submersa que mantém o soro em constante movimentação. Foi feito um teste cíclico de fadiga de componente femoral de artroplastia de quadril, com torção, seguindo determinações das normas ISO 7206/89, parte 4 e ASTM F 1612/95, e utilizada para o teste a Prótese Femoral Cimentada Modelo Alpha ® da empresa Baumer ®, haste polida de 150 mm e off-set de 37,5 mm. Também foi feito um ensaio para verificação de trincas seguindo determinações da Norma ABNT NBR ISO 9583/1997. Durante as 139 horas previstas para o teste de fadiga do componente femoral, a máquina de ensaio não apresentou problemas mecânicos, demonstrando eficiência e o êxito na confecção de uma máquina de ensaios cíclicos para testes biomecânicos
Titre en anglais
Development of machine of cyclic movements for biomechanical tests
Mots-clés en anglais
biomaterial
biomechanical trial
cyclic movement
fatigue
Resumé en anglais
The human being locomotes using the complex neuro-muscle-skeletal system, what confers him life quality. Parts of the skeletal system can submit to treatment or even to the substitution for the employment of strange materials to the human body but that provoke small biological reaction and they need to be projected in way to support every resulting tension of the human movement. The objective of this work was to develop a machine of cyclic trial for biomechanical tests using national technology. The machine has an activation system by means of a triphasic motor of 2 HP, 1800 rpm; a system of transmission of cyclic loads using an eccentric axis, that activates a piston, that promotes the movement of two levers that transmit the load for the components at be tested. There is a frequency inverter for control of the number of cycles of the motor, a reservoir of physiologic serum with a system that maintains the serum heated up to 36-38 ºC, and a submerged hydraulic bomb that maintains the serum in constant movement. It was made a cyclic test of fatigue of femoral component of hip arthroplasty, with torsion, following determinations of the norms ISO 7206/89, part 4 and ASTM F 1612/95, and used for the test the Prosthesis Femoral Cemented Model Alpha ® of the company Baumer ®, polished stem of 150 mm and off-set of 37,5 mm. It was also made a trial for verification of cracks following determinations of the norm ABNT NBR ISO 9583/1997. During the 139 hours foreseen for the test of fatigue of the femoral component, the trial machine didn’t present mechanical problems, demonstrating efficiency and the success in the production of a machine of cyclic trials for biomechanical tests
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2004-05-04
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.