• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.82.2012.tde-15022013-142541
Documento
Autor
Nombre completo
Juliana Pereira de Souza
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2012
Director
Tribunal
Marques, Paulo Mazzoncini de Azevedo (Presidente)
Bulcão Neto, Renato de Freitas
Nunes, Altacilio Aparecido
Pazin Filho, Antonio
Traina, Agma Juci Machado
Título en portugués
Modelo de qualidade para o desenvolvimento e avaliação da viabilidade clínica de sistemas de recuperação de imagens médicas baseadas em conteúdo
Palabras clave en portugués
Imagens médicas
Informática médica
Modelos de qualidade
Qualidade de software
Sistemas de recuperação de imagens baseada em conteúdo
Resumen en portugués
Com a crescente utilização de imagens médicas na prática clínica, torna-se necessária a introdução de tecnologias que garantam o armazenamento, indexação e recuperação eficaz dessas imagens. O sistema de recuperação de imagens médicas baseada em conteúdo (S-CBIR) compõe a base de tecnologias computacionais que oferecem aos usuários médicos aplicativos para apoio ao diagnóstico, sendo capaz de responder a consultas por similaridade por meio de características pictóricas extraídas das imagens médicas. Embora as pesquisas em S-CBIR tenham iniciado há quase duas décadas, atualmente existe uma discrepância em relação à quantidade de trabalhos publicados na literatura e os sistemas que, de fato, foram implementados e avaliados. Além disso, muitos protótipos vêm sendo discutidos, mas até o final da escrita desta tese, não foram encontradas evidências de que algum deles esteja disponível comercialmente. Essa limitação é conhecida pela comunidade científica da área por gap de aplicação. Em geral, isso ocorre devido à dificuldade dessas aplicações em superar alguns desafios, como a divergência entre os resultados obtidos automaticamente pelo sistema e aqueles esperados pelos médicos (gap semântico), entre outros gap. Outros fatores também podem ser relatados, como a tendência da não utilização de modelos de qualidade sistematizados para o desenvolvimento dos sistemas, e a carência de modelos que sejam específicos no domínio de aplicação. Com base nesses desafios e em boas práticas de métodos, técnicas e ferramentas da Engenharia de Software, esta tese apresenta um Modelo de Qualidade para melhorias de S-CBIR (MQ-SCBIR), que tem por objetivo apoiar o desenvolvimento e avaliação de S-CBIR, a partir de diretrizes para aumentar o nível de qualidade, buscando a superação do gap de aplicação. O MQ-SCBIR foi construído com base em: evidências adquiridas por meio de uma revisão sistemática e pesquisa empírica sobre como esses sistemas vêm sendo desenvolvidos e avaliados na literatura e na prática; resultados da avaliação de um S-CBIR baseados em testes heurísticos em um ambiente real; modelos bem estabelecidos, como o Capability Maturity Model Integration e Melhoria de Processo do Software Brasileiro; e em experiências pessoais. O uso do MQ-SCBIR pode trazer benefícios para as organizações desenvolvedoras, como a redução da complexidade no desenvolvimento, incluindo a garantia de implementação de boas práticas de qualidade de software e práticas específicas para a superação das limitações de S-CBIR durante o processo de desenvolvimento.
Título en inglés
A quality model to develop content-based image retrieval systems and assess their clinical feasibility
Palabras clave en inglés
Content-based image retrieval systems
Medical images
Medical informatics
Quality models
Software quality
Resumen en inglés
The development of technologies for storing, indexing and recovering clinical images is paramount to support the increasing use of these images in clinical diagnostic evaluation. Content-based image retrieval systems (CBIR-S) are some of the main computational technologies which offer physicians different applications to aid diagnostic processes. They allow similarity queries by extracting pictorial features from medical images. Even though research on S-CBIR started almost two decades ago, there are discrepancies regarding the amount of studies available in the literature and the number of systems which have actually been implemented and evaluated. Many prototypes have been discussed, but up to the moment this study was completed we found no evidence that any of those systems are either commercially available or being currently used in clinical practice. This limitation is known as application gap. In general, this happens due to the difficulty to overcome some obstacles, such as the differences between the results retrieved automatically by the system and those expected by the physicians (semantic gap). Other factors can also be described, such as the tendency towards not using systematic quality models to develop these systems and the lack of specific models for this domain of application. Based on these challenges and also on best practice methods, techniques and tools from software engineering, this work presents a quality model to improve S-CBIR systems (QM-CBIRS). It strives to tackle limitations during the development process by overcoming the semantic gap. The QM-CBIRS was built upon evidence gathered by means of a systematic review on the state-of-the-art and empiric research on the development and evaluation of these systems. Apart from that, results from the assessment of a CBIR-S based on empiric tests and on diagnostic tasks in radiology and well-established software quality models, such as CMMI and the Brazilian Software Improvement Process are presented. Apart from that, results from the assessment of a CBIR-S based on empiric tests and on diagnostic tasks in radiology and well-established software quality models, such as CMMI and the Brazilian Software Improvement Process are presented. The use of QM-CBIRS might be beneficial to development teams in many ways, for example, by increasing the quality of CBIR systems and reducing complexity, thus surpassing limitations from CBIR systems during the development process.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-05-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.