• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.1994.tde-30042009-094938
Documento
Autor
Nombre completo
Paulo Mazzoncini de Azevedo Marques
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 1994
Director
Tribunal
Almeida, Adelaide de
Baffa Filho, Oswaldo
Mascarenhas, Nelson Delfino D Avila
Nascimento, Otaciro Rangel
Slaets, Annie France Frere
Título en portugués
Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas.
Palabras clave en portugués
Função de espalhamento de ponto
Função de transferência de modulação
Garantia de qualidade em imagem radiológica
Resumen en portugués
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem.
Título en inglés
Evaluating the focal sopt MTF in all radiological field location by computer simulation.
Palabras clave en inglés
Modulation transfer function
Point spread function
Radiological imaging quality assurance
Resumen en inglés
In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2009-05-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.