Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.76.2013.tde-19062013-080945
Documento
Autor
Nome completo
Marcos Antonio Moura de Sousa
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2013
Orientador
Banca examinadora
Oliveira Junior, Osvaldo Novais de (Presidente)
Alves, Neri
Guimarães, Francisco Eduardo Gontijo
Título em português
Modelos de circuitos equivalentes para explicar espectros de impedância de dispositivos de efeito de campo
Palavras-chave em português
Bicamadas de PAMAM/SWNT
Circuitos equivalentes
Dispositivos de efeito de campo
Espectroscopia de impedância
Sensores EIS
Resumo em português
Biossensores que empregam dispositivos de efeitos de campo podem ser obtidos em diversas arquiteturas, incluindo dispositivos Eletrólito-Isolante-Semicondutor (EIS), que são capacitores em que o eletrodo metálico é substituído por um filme e uma solução. Medindo-se a capacitância em função do potencial aplicado, é possível detectar variações de pH oriundas de reações ou interações entre o filme e o analito. Nesta dissertação, sensores foram produzidos com a adsorção de filmes automontados de dendrímero (PAMAM) e nanotubos de carbono (SWNT) num chip. Medidas de espectroscopia de impedância foram realizadas para investigar o crescimento de cada bicamada do filme automontado, e os dados foram analisados com circuitos equivalentes que continham uma capacitância de dupla camada, um elemento de fase constante e uma capacitância para a região de depleção. Para o chip, os melhores ajustes foram obtidos na frequência de 2 kHz, em que a concentração de dopantes foi 6,6x1020 m-3 para o chip com isolante de SiO2 e de 1,1x1021 m-3 para o chip com isolante de SiO2/Ta2O5. O potencial de banda plana foi -0,2 V e -0,06V, respectivamente. Para os chips recobertos com os filmes de PAMAM/SWNT, observamos que a região de depleção é causada pelas cargas positivas do PAMAM. Com relação às implicações para biossensores, verificamos que o desempenho ótimo deve ser obtido com 3 bicamadas de PAMAM/SWNT. Isso pode explicar a observação empírica na literatura de que existe uma espessura ideal dos filmes para um desempenho otimizado.
Título em inglês
Use of equivalent circuit models to explain impedance spectra in field-effect devices
Palavras-chave em inglês
EIS sensors
Equivalent circuits
Field-effect devices
Impedance spectroscopy
PAMAM/SWNT bilayers
Resumo em inglês
Biosensors based on field effect devices can be produced with several architectures, including Electrolyte-Insulator-Semiconductor (EIS) devices, which are capacitors where conventional metal electrodes are replaced by a sensing layer and an electrolyte solution. By measuring the capacitance as a function of the bias voltage, it is possible to detect pH changes that may originate from reactions or interactions between the film in the sensing unit and the analyte. In this study sensors were obtained by adsorbing layer-by-layer (LbL) films made with dendrimers (PAMAM) and carbon nanotubes (SWNT) on a semiconductor chip. Impedance spectroscopy measurements were performed to monitor the growth of each bilayer in the LbL film, whose data were analyzed with equivalent circuits containing a double-layer capacitance, a constant phase element and a capacitance for the depletion region. The results for the semiconductor chip could be best fitted for a frequency of 2 kHz, where the doping concentration was 6.6 x1020 m-3 for the insulating SiO2 layer and 1.1 x1021 m-3 for the SiO2/Ta2O5 layer. The flat band voltage was -0.2 V and -0.06 V, respectively. In the analysis of the chip coated with different numbers of PAMAM/SWNT bilayers, we found that the depletion region appears as a contribution from the positive charges in the PAMAM layer. With regard to implications for biosensors, we found that optimized performance should be reached with three PAMAM/SWNT bilayers, which may explain the empirical finding in the literature that an ideal thickness exists for enhanced performance.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2013-06-20
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.