• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.2002.tde-14102014-163814
Documento
Autor
Nombre completo
Flavio Teles Carvalho da Silva
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2002
Director
Tribunal
Bagnato, Vanderlei Salvador (Presidente)
Marcassa, Luis Gustavo
Nussenzveig, Paulo Alberto
Roda, Valentin Obac
Sartori, Jose Carlos
Título en portugués
Metrologia de tempo e frequência: relógio de feixe de césio e chafariz com átomos frios
Palabras clave en portugués
Física atômica
Tempo e freqüência
Resumen en portugués
Esta tese faz parte de um programa de estabelecimento de metrologia científica de tempo e frequencia no Brasil. Com este objetivo, estamos desenvolvendo dois padrões de frequência atômicos: um feixe térmico de 133Cs bombeado opticamente, em funcionamento, e outro de átomos frios, em fase de conclusão. Para caracterizarmos o relógio de feixe, realizamos a medida de sua razão sinal ruído, do perfil de velocidade do feixe térmico e dos deslocamentos de frequências presentes neste padrão. A estabilidade de frequência de curto período medida neste relógio e de σ(τ) =(1.78x10-11) x τ-1/2 . O processo de construção de relógio de átomos frios (sistemas de vácuo, sistema de controle, cavidade e sintetizadores de microondas) é apresentado em detalhes
Título en inglés
Time and Frequency metrology: Cesium atomic beam clock and a fountain with cold atoms
Palabras clave en inglés
Atomic physics
Time and frequency
Resumen en inglés
This work is part of the program of the establishment of time and frequency metrology in Brazil. To realize this objective we are developing two atomic frequency standards: optically pumped cesium-beam frequency standard, currently in operation, and an atomic fountain, which is in progress. The performance of the Cs beam standard was evaluated by the measurements of the signal-to-noise ratio, velocity distribution and some major frequency shifts. The measurement short-term stability is σ(τ) =(1.78x10-11) x τ-1/2 . The atomic fountain construction process (vacuum chamber, the control system, microwave cavities and synthesizers) is described in detail
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
FlavioSilvaD.pdf (3.46 Mbytes)
Fecha de Publicación
2014-10-20
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.