• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.76.2020.tde-13052020-093747
Documento
Autor
Nombre completo
David Antônio Sbrissa Neto
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2019
Director
Tribunal
Milori, Debora Marcondes Bastos Pereira (Presidente)
Guimarães, Francisco Eduardo Gontijo
Romero, Roseli Aparecida Francelin
Saito, Jose Hiroki
Vieira, Marcelo Andrade da Costa
Título en portugués
Diagnóstico de doenças de soja através da emissão de fluorescência das folhas: estudo de caso para Ferrugem asiática e "Haste verde e retenção foliar"
Palabras clave en portugués
Aprendizado de máquina
Diagnóstico precoce
Doenças de soja
Fluorescência
Resumen en portugués
O presente trabalho investiga a emissão de fluorescência de plantas de soja contaminadas por duas importantes doenças de soja para o cenário brasileiro: a Ferrugem Asiática e a Haste Verde e Retenção Foliar – popularmente conhecida como soja louca II. Para tal, foi realizado um experimento nas dependências da EMBRAPA Soja, localizada em Londrina-PR, com a expressão de ambas as doenças em plantas de soja, além de um grupo controle para comparação. Foram obtidas cinco coletas caracterizadas como Assintomáticas para HVRF e três coletas para as Assintomáticas FA. Foram utilizadas três técnicas de fluorescência: o estereomi-croscópio comercial SteReo Lumar.V12 com excitação em λ=365 nm (EM-365), a Laser Induced Fluorescence Spectroscopy (LIFS) e Laser Induced Fluorescence Imaging (LIFI), ambas com excitação em λ=405 nm. Como principais resultados, destaca-se a contribuição das bandas de emissão em 520 nm e 740 nm para caracterização das assintomáticas. Na etapa de classificação, a taxa de acerto na predição dos grupos de teste foi elevada, com mais de 90% de acurácia total da classificação para todas as metodologias de fluorescência. No caso HVRF, a instrumentação LIFI apresentou a maior acurácia de teste, com 98%. No caso FA, as instrumentações LIFI e LIFS apresentaram 93% e 94% de acurácia, respectivamente. Essas informações comprovam a hipótese fundamental do trabalho, sobre a capacidade discriminatória das emissões de fluorescência de plantas assintomáticas com relação às plantas sadias, com ênfase às técnicas LIFS e LIFI, que podem ser adaptadas para instrumentações portáteis. Além disso, foi realizado um teste de classificação para as três classes – Sadia, Assintomática HVRF e Assintomática FA – para todas as instrumentações. Os resultados desse teste foram igualmente consistentes em comparação com os resultados para duas classes, e permitem concluir que os dados de fluorescência obtidos pelas instrumentações são eficientes na caracterização distinta de cada classe.
Título en inglés
Diagnosis of soybean diseases through leaf fluorescence emission: case study for Asian rust and "Green Stem and Leaf Retention"
Palabras clave en inglés
Early diagnosis
Fluorescence
Machine learning
Soybean
Resumen en inglés
The aim of this work is to analyze the fluorescence emission of soybean plants contaminated by two important diseases for the Brazilian scenario: Asian Rust and Green Stem and Leaf Retention - popularly known as soja louca II. For this purpose, an experiment was performed in EMBRAPA Soja, located in Londrina-PR, with the expression of both diseases in soybean plants, as well as a control group for comparison. Five collections characterized as asymptomatic for HVRF and three collections for asymptomatic FA were obtained, and each collection consisted of 32 samples from each group. Three fluorescence techniques were used: The SteReo Lumar.V12 commercial stereomicroscope with excitation at λ = 365 nm (EM-365); the Laser Induced Fluorescence Spectroscopy (LIFS) and Laser Induced Fluorescence Imaging (LIFI) systems, both with λ=405 nm excitation. The main results of this analysis are the contribution of the emission bands at 520 nm and 740 nm for the characterization of asymptomatic ones. In the classification stage, the prediction accuracy of the test groups was high, with over 90% of total classification accuracy for all fluorescence methodologies. In the HVRF case, the LIFI instrumentation presented the highest test accuracy, with 98%. In the FA, the LIFI and LIFS instrumentations presented 93% and 94% accuracy, respectively. This information confirms the fundamental hypothesis of the work, regarding the discriminatory capacity of fluorescence emissions of asymptomatic plants, compared to healthy plants, with emphasis on LIFS and LIFI techniques, which can be adapted for portable instrumentation. In addition, a classification test was performed with the three classes – Healthy, Asymptomatic HVRF and Asymptomatic FA - for all instrumentations. Their results were equally consistent with the results for two classes, and allow us to conclude that the fluorescence data obtained by the instrumentations are efficient in the distinct characterization of each class.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-05-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.