Disertación de Maestría
DOI
https://doi.org/10.11606/D.76.2000.tde-06122013-164129
Documento
Autor
Nombre completo
Rogério Ferreira Xavier
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2000
Director
Tribunal
Tannus, Alberto (Presidente)
Baffa Filho, Oswaldo
Schneider, José Fábian
Título en portugués
Desenvolvimento e construção de bobinas de gradiente com blindagem ativa (Active Shielding) com aplicação em imagens por RMN
Palabras clave en portugués
Bobinas gradientes blindadas
Imagens por RMN
Resumen en portugués
As bobinas ativamente blindadas (actively shielded) melhoram a performance das bobinas de gradiente ao cancelar o campo magnético na parte externa da bobina primária, evitando a degradação do campo no seu interior devido às correntes induzidas (eddy currents). O presente trabalho resultou na construção de um conjunto de bobinas de gradientes ativamente blindadas (Gx, Gy e Gz ), de geometria cilíndrica e acesso axial, com diâmetro de volume útil de 10cm para imagens (field of view), com campos de gradiente de aproximadamente 8.0 G/cm para r=0, com uma máxima distorção de campo de 5% neste volume, onde foi observado um efetivo cancelamento do campo externo, o que evita correntes induzidas nas partes metálicas internas do magneto OXFORD de 2.0 Tesla horizontal de 30cm de diâmetro, no qual serão empregadas. Alguns resultados prévios foram obtidos com um protótipo transversal, em apenas uma direção, e também com um conjunto de bobinas de gradiente para utilização em obtenção de imagens microscópicas de ESR pulsado. As bobinas foram projetadas utilizando-se a técnica de densidade de corrente, que se baseia na abordagem de campo alvo (target field) e também foi empregado o método de "simulated annealing" para otimização do desenho. Este sistema de gradientes apresenta também uma baixa indutância, o que permitirá chaveamentos rápidos (~0.1 ms). Na análise do campo de gradiente gerado foi utilizado o método de diferença de fase, confirmando a eficiência da técnica de densidade de corrente utilizada nos cálculos para a construção destas bobinas de gradiente
Título en inglés
Development and construction of Active Shielding gradient coils with application in Magnetic Resonance Imaging
Palabras clave en inglés
Magnetic resonance imaging
Shielded gradient coils
Resumen en inglés
Actively shielded coils are designed to improve the performance of a gradient coil set by canceling the magnetic field in the region outside the body of the coil, avoiding degradation of the field in its interior due to eddy currents induced in the electric vicinity. The present work resulted on the construction of a shielded gradient coil set (Gx, Gy e Gz) with cylindrical geometry and axial access, with volume diameter of 1 O cm (imaging FOV) and gradient field intensity of 8.0 Gauss/cm in r=0. The maximum gradient distortion aim was 5% inside that volume, along with an effective cancellation of the field close to the inner metallic parts of the OXFORD 2.0 Tesla 31 cm bore horizontal magnet. Preliminary results were obtained with a prototype, which included only one transverse channel, and a miniature set with the same geometry was specially designed to perform micro imaging experiments using pulsed Electron Paramagnetic Resonance. Coils were designed using the current density technique, which is based on the target field approach and simulated annealing for optimization. The gradient systems described here present also a low inductance necessary to perform fast switching (~0.1 ms). For the analysis of the performance of the gradients we used the method of phase reference, confirming the efficiency of the current density technique used on the design of the gradient sets
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
RogerioXavierM.pdf (66.69 Mbytes)
Fecha de Publicación
2013-12-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.