• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.76.2012.tde-11102012-163617
Document
Author
Full name
Jaciara Cássia de Carvalho Santos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Zucolotto, Valtencir (President)
Souza, Flavio Leandro de
Wohnrath, Karen
Title in Portuguese
Imobilização da enzima glicose oxidase em filmes nanoestruturados para aplicação em biossensores
Keywords in Portuguese
Biossensores
Glicose
Imobilização
Nanopartículas de ouro
Técnica de Automontagem
Abstract in Portuguese
Aplicações de nanomateriais em biossensores têm recebido muito interesse nos últimos anos. Entre os vários tipos de biossensores estudados, sensores de glicose têm recebido destaque devido a sua importância em diagnósticos clínicos. Apesar do grande avanço no monitoramento de glicose nas últimas décadas, ainda há muitos desafios para alcançar um monitoramento de glicemia continuo, clinicamente preciso, em conexão a um sistema fechado otimizado para a entrega de insulina no corpo. Esta dissertação descreve a fabricação de filmes layer-by-layer (LbL) obtidos a partir da enzima glicose oxidase (GOx) e dos polieletrólitos poli(amidoamina) de geração 4 (PG4) e o hibrido PG4 com as nanopartículas de ouro (PG4AuNp). As nanopartículas de ouro foram sintetizadas em meio aquoso usando o dendrímero PG4, o ácido cloroáurico (HAuCl₄4) e ácido fórmico. As medidas de espectroscopia UV-Vis dos filmes automontados em substratos de quartzo mostraram um crescimento linear em função do número de bicamadas depositados apenas para o filme PG4-GOx. No filme PG4AuNp-GOx o crescimento não é linear. Em adição às caracterizações ópticas, estrutural e eletroquímica, os filmes LbL, depositados sobre substratos de vidro recoberto com óxido de índio (ITO) foram testados para a atuação em biossensores de peróxido de hidrogênio e de glicose. A biofuncionalidade da GOx e a viabilidade do método como biossensor foi demonstrada pelo aumento da corrente em função das sucessivas adições de alíquotas de glicose à solução. Os filmes sem nanopartículas não foram sensíveis a glicose. O biossensor com melhor desempenho foi o ITO-(PG4AuNp-GOx) com 5 bicamadas, que mostrou-se linear na faixa de 0 a 4,8 mM de glicose com sensibilidade 0,013 μA/mM e limite de detecção 0,44 mmolL ¹.
Title in English
Glucose oxidase immobilization on nanostructured thin films for application in biosensors
Keywords in English
Biosensors
Glucose
Gold Nanoparticles
Immobilization
Self-assemble technique
Abstract in English
Applications of nanomaterials for biosensors have been target of substantial research in the last years. Among a large number of biosensors, glucose biosensors have attracted attention due to their applications in clinical diagnostics. Despite the remarkable progress in glucose biosensors in the last decades, there are still many challenges in achieving clinically accurate continuous glycemic monitoring in connection to closed-loop systems aimed at optimal insulin delivery. This dissertation describes the fabrication of layer-by-layer (LbL) films obtained from the enzyme glucose oxidase (GOx) and the polyelectrolytes poli(amidoamine) generation 4 (PG4) and PG4 containing gold nanoparticles (PG4AuNp). Gold nanoparticles were synthesized in aqueous solution using formic acid, PG4 and HAuCl ₄. UV-vis spectroscopy showed a linear growth on quartz substrate only in the system PG4-GOx. In addition to the optical, structural and electrochemistry investigation, these LbL films deposited on ITO-coated glass were employed as electrochemical glucose biosensors. The biofunctionality of GOx and feasibility of the method as biosensor are demonstrated by the increase of reduction current upon additions of successive aliquots of glucose. The biosensor ITO-(PG4AuNp-GOx) ₅ with the optimum performance had a detection limit of 0.44 mmolL¹ with a linear response in the range from 0 to 4.8 mmolL¹ and sensibility 0.013μA/mmolL ¹.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-10-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.