• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.75.2023.tde-29012024-103628
Document
Auteur
Nom complet
Lucas Vinicius Leite Martoni
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2023
Directeur
Jury
Machado, Sergio Antonio Spinola (Président)
Bernardi, Juliana Cancino
Correia, Adriana Nunes
Pereira, Paulo Augusto Raymundo
Souza, Djenaine de
Titre en portugais
Desenvolvimento de sensores fotoeletroquímicos impressos modificados com nanoesferas de carbono para quantificação de poluentes emergentes em amostras de água de abastecimento
Mots-clés en portugais
eletrodos impressos
ftalocianina de cobalto (II)
hidroquinona
nanoesferas de carbono
paracetamol
poluentes emergentes
Resumé en portugais
Nesta tese, foram desenvolvidos métodos fotoeletroquímicos miniaturizados a partir de eletrodos impressos (SPEs) modificados com nanoesferas de carbono (CSS) e com essas associadas ao fotossensibilizador ftalocianina de cobalto (II) CoPc, e foram aplicados na quantificação de poluentes emergentes. As CSS foram sintetizadas a partir da glicose, usando rota ambientalmente amigável e, por meio de diferentes técnicas de caracterização, foi possível concluir que apresentaram formato esférico, com diâmetro médio de 150 ±30 nm, band gap (Eg) de 1,3 eV e cuja superfície era composta por carbono (81,95%) e oxigênio (18,05%), sendo que a hibridização dos átomos de carbono era de 50,4% de sp3 e 46,4% de sp2. SPEs foram modificados com as CSS sintetizadas e aplicados na determinação de hidroquinona (HQ), tendo o sensor apresentado faixa linear de 3,0 a 23,0 µmol L-1, sensibilidade de 0,069 (±0,004) µA L µmol -1 e limite de detecção (LOD) de 2,7 µmol L-1. SPEs também foram modificados com as CSS sintetizadas e com o fotossensibilizador CoPc e foram aplicados na quantificação de paracetamol em amostras de água de abastecimento e de medicamento (comprimido). Esse sensor apresentou faixa linear de 1,5 a 14,0 µmol L-1, sensibilidade de 0,083 (±0,002) µA L µmol-1 e LOD de 0,85 µmol L-1. Quando comparado com o eletrodo modificado apenas com as CSS, o valor da sensibilidade foi cerca de 2,8 vezes maior e do LOD cerca de 1,34 vezes menor para o eletrodo em que há a presença do fotossensibilizador. Também foi verificado que os sensores desenvolvidos eram seletivos (valores de interferência inferiores a 20% nos dois casos) e reprodutíveis (verificado em experimentos intra-dia e interdias), sendo que no sensor em que há a presença da CoPc também foi estudada sua estabilidade ao longo do tempo, tendo sido constatado que era estável por 57 dias.
Titre en anglais
Development of screen-printed photoelectrochemical sensors modified with carbon spherical shells for emerging pollutants quantification in water samples
Mots-clés en anglais
acetaminophen
carbon spherical shells
cobalt (II) phthalocyanine
emerging pollutants
hydroquinone
screen-printed electrodes
Resumé en anglais
In this work, miniaturized photoelectrochemical (PEC) sensors based on screen-printed electrodes (SPEs) modified with carbon spherical shells (CSS) and CSS associated with the photosensitizer cobalt phthalocyanine (II) CoPc were developed and applied for emerging pollutants quantification. CSS were synthesized by glucose, by an eco-friendly route, and characterized by different techniques. It was concluded that CSS have spherical shape, with average diameter of 150 ±30 nm, band gap (Eg) of 1.3 eV, and surface composition of 81.95% of carbon and 18.05% of oxygen, with 50.4% of those carbons in the sp3 and 46.4% in the sp2 hybridization. SPEs were modified with synthesized CSS and applied in hydroquinone (HQ) determination, having the sensor presented linear range from 3.0 to 23.0 µmol L-1, sensitivity of 0.069 (± 0.004) µA L µmol-1 and limit of detection (LOD) of 2.7 µmol L-1. SPEs were also modified with CSS and with the photosensitizer CoPc and were applied in the quantification of acetaminophen (paracetamol) in tap water and tablet. This sensor showed a linear range from 1.5 to 14.0 µmol L-1, sensitivity of 0.083 (±0.002) µA L µmol-1, and LOD of 0.85 µmol L-1. When compared with SPE modified only with CSS, the sensitivity was 2.8 folds higher and LOD 1.34 times lower for the electrode modified with CSS and CoPc. Other parameters were evaluated, and it was verified that both sensors were selective (values of interference less than 20% for the studied compounds) and reproductible (verified intra-day and interdays), and in the sensor which there is the presence of CoPc, the stability over the time was also studied, having be found to be stable for 57 days.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2024-01-29
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.