• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2019.tde-28082018-093338
Documento
Autor
Nombre completo
Thiago Serafim Martins
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2018
Director
Tribunal
Machado, Sergio Antonio Spinola (Presidente)
Sales, Lucia Helena Mascaro
Stradiotto, Nelson Ramos
Lanza, Marcos Roberto de Vasconcelos
Título en portugués
Desenvolvimento de um sensor eletroquímico para furosemida baseado em superfície de grafite de lápis modificada com filme polimérico de Ni-Salen e nanopartículas de Ni(OH)2/C
Palabras clave en portugués
furosemida
nanopartículas de Ni(OH)2
polímero condutor
sensor eletroquímico
[Ni(salen)]
Resumen en portugués

Neste trabalho, um sensor eletroquímico avançado baseado em eletrodo de grafite de lápis modificado via eletropolimerização do monômero de N,N'-bis(salicilideno)etilenodiaminoníquel(II) na presença de nanopartículas de Ni(OH)2 suportadas em carbono (chamado aqui de poli[Ni(salen)] e Ni(OH)2C) foi desenvolvido e investigado para quantificação de furosemida (FUR) em meio alcalino. O sensor eletroquímico e seus componentes foram extensivamente caracterizados por técnicas físico-químicas, enquanto que o processo de oxidação da furosemida foi investigado por espectroscopia no infravermelho com transformada de Fourier in situ (FTIV in situ). Estes resultados indicam que a oxidação da furosemida nestas condições leva à formação de 2-amino-4-cloro-5-sulfamoilbenzoato e 5-hidroxi-furano-2-carboxilato. A resposta eletroquímica do eletrodo de grafite modificado (EGM) para a determinação de furosemida foi medida por voltametria cíclica (VC). A curva de calibração (mudança de corrente de pico voltamétrico versus concentração de FUR) apresentou uma faixa linear de 2,5 × 10-10 mol L-1 a 2,7 × 10-9 mol L-1 com um limite de detecção calculado tão baixo quanto 1,45 × 10-10 mol L-1 nas condições otimizadas, que é menor do que os valores relatados na literatura. A sensibilidade ultrabaixa obtida com sensor desenvolvido foi atribuída a um efeito sinérgico entre o filme de poli[Ni(salen)] e as nanopartículas de Ni(OH)2/C.

Título en inglés
Development of an electrochemical sensor for furosemide based on pencil graphite surface modified with Ni-Salen polymer film and Ni(OH)2/C nanoparticles
Palabras clave en inglés
conducting polymer
electrochemical sensor
furosemide
Ni(OH)2 nanoparticles
[Ni(salen)]
Resumen en inglés

In this work, an advanced electrochemical sensor based on pencil graphite electrode modified via electropolymerization of the N,N'-bis(salicylidene)ethylenediaminonickel(II) monomer in the presence of carbon supported Ni(OH)2 nanoparticles (here called as poly[Ni(salen)] and Ni(OH)2/C) was developed and investigated for furosemide (FUR) quantification in alkaline medium. The electrochemical sensor and its components were extensively characterized by physico-chemical techniques, while the furosemide oxidation process was investigated by in situ Fourier transform infrared spectroscopy (in situ FTIR). These results indicate that the oxidation of furosemide in these conditions leads to the formation of 2-amino-4-chloro-5-sulfamoylbenzoate and 5-hydroxy-furan-2-carboxylate. The electrochemical response of the modified graphite electrode (MGE) for the determination of furosemide was measured by cyclic voltammetry (CV). The calibration curve (change of voltammetric peak current vs. FUR concentration) presented a linear range from 2.5 × 10-10 mol L-1 to 2.7 × 10-9 mol L-1 with a calculated limit of detection as low as 1.45 × 10-10 mol L-1 under the optimized conditions, which is lower than values reported in the literature. The ultra-low sensitivity obtained with the MGE sensor was attributed to a synergistic effect between the poly[Ni(salen)] film and Ni(OH)2/C nanoparticles.

 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.