• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.75.2022.tde-22062022-102046
Document
Auteur
Nom complet
Juliana Soares da Silva Burato
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2022
Directeur
Jury
Lanças, Fernando Mauro (Président)
Bottoli, Carla Beatriz Grespan
Brondi, Silvia Helena Govoni
Gomes, Paulo Clairmont Feitosa de Lima
Vieira, Eny Maria
Titre en portugais
Desenvolvimento de colunas miniaturizadas do tipo PLOT para cromatografia líquida de alta eficiência
Mots-clés en portugais
colunas do tipo PLOT
cromatografia líquida
eletrospray
espectrometria de massas
ionização por elétrons
Resumé en portugais
A cromatografia é uma das principais ferramentas para a separação de compostos químicos. A cromatografia gasosa obteve seu ápice de eficiência ainda nos anos 1950, através do uso de colunas analíticas tubulares abertas com diâmetro interno miniaturizado e ao acoplamento com técnica de detecção de espectrometria de massas. A cromatografia líquida segue a mesma tendência, porém ainda não obteve seu ápice eficiência devido às limitações instrumentais que tem sido gradualmente contornadas. Diante desse contexto essa tese de doutorado teve como objetivo o desenvolvimento de colunas miniaturizadas tubulares abertas do tipo PLOT para cromatografia líquida de alta eficiência. A metodologia de preparo das colunas se mostrou concisa e reprodutível; foram desenvolvidas colunas do tipo PLOT com fase estacionária de poli(estireno-divinilbenzeno) e com diâmetro interno de 8 e 25 µm. As colunas desenvolvidas foram utilizadas como colunas analíticas para cromatografia líquida em dois acoplamentos diferentes, sendo o primeiro a um espectrômetro de massas com fonte de ionização por impacto de elétrons, demonstrado, pela primeira vez, que essas colunas são compatíveis com essa fonte sem a necessidade de uma interface, e o segundo a um espectrômetro de massas com fonte de ionização por electropray. A validação da aplicabilidade das colunas foi realizada a partir de estudos de figuras de mérito extraídas através de separação cromatográficas de moléculas pequenas como toxinas e pesticidas de matrizes alcoólicas, diferentemente da maior parte dos trabalhos publicados nesta área nas quais essas colunas são utilizadas para separar macromoléculas. Foi explorado a presença de ocratoxina A em saquê que apresentou limite de quantificação de 10 µg mL-1 e também a presença de pesticidas em rum no qual a atrazina e o carbofurano tiveram limite de detecção e quantificação a concentração de 1 µg mL-1, já a clomazona e a hexazonina apresentaram valores inferiores a 0,1 µg mL-1.
Titre en anglais
Development of miniaturized PLOT-type columns for high performance liquid chromatography
Mots-clés en anglais
Electron Ionization
Electrospray
Liquid chromatography
Mass Spectrometry
PLOT columns
Resumé en anglais
Chromatography is one of the main tools for the separation of chemical compounds. Gas chromatography reached its peak of efficiency in the 1950s, through the use of open tubular analytical columns with miniaturized internal diameter and coupling with mass spectrometry detection technique. Liquid chromatography follows the same trend, but has not yet reached its peak efficiency due to instrumental limitations that have been gradually overcome. Given this context, this doctoral thesis aimed to develop miniaturized open tubular columns of the PLOT type for high performance liquid chromatography. The column preparation methodology proved to be concise and reproducible; PLOT-type columns with poly(styrene-divinylbenzene) stationary phase and internal diameters of 8 and 25 µm were developed. The developed columns were used as analytical columns for liquid chromatography in two different couplings, the first being a mass spectrometer with an electron impact ionization source, demonstrating, for the first time, that these columns are compatible with this source without the need for from an interface, and the second to a mass spectrometer with an electropray ionization source. The validation of the applicability of the columns was carried out from studies of figures of merit extracted through chromatographic separation of small molecules such as toxins and pesticides from alcoholic matrices, unlike most of the works published in this area in which these columns are used to separate macromolecules. The presence of ochratoxin A in sake was explored, which presented a limit of quantification of 10 µg mL-1 and also the presence of pesticides in rum in which atrazine and carbofuran had a limit of detection and quantification at a concentration of 1 µg mL-1, clomazone and hexazonin presented values lower than 0.1 µg mL-1.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-06-23
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.