Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.75.2012.tde-19102012-161738
Document
Auteur
Nom complet
Paulo Falco Cobra
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2012
Directeur
Jury
Colnago, Luiz Alberto (Président)
Azevêdo, Eduardo Ribeiro de
Plepis, Ana Maria de Guzzi
Titre en portugais
Uso da relaxometria de RMN no domínio do tempo para estudo de íons paramagnéticos em solução
Mots-clés en portugais
íons paramagnéticos
ressonância magnética nuclear
Resumé en portugais
O estudo de soluções iônicas tem grande importância na química analítica. Na RMN, vários pesquisadores se dedicam ao entendimento do papel de íons paramagnéticos nos tempos de relaxação longitudinal (T1) e transversal (T2). A maioria dos trabalhos nesta área se dedicou ao estudo destas influências no T1, que é uma medida bem mais lenta do que a de T2. Assim, neste trabalho se estudou as implicações da relaxometria de T2 por RMN no domínio do tempo (RMN-DT) em soluções de íons paramagnéticos. A partir deste estudo, demonstrou-se a correlação linear entre a taxa de relaxação transversal (1/T2) e a concentração dos íons paramagnéticos. Com isso, usou-se esta metodologia na determinação de constantes do produto de solubilidade (Kps) dos hidróxidos Fe(OH)3, Cu(OH)2 e Mn(OH)2. A determinação da constante de solubilidade (Kps) tem grande importância e aplicação em química, principalmente na separação de íons por precipitação. Foi possível determinar com grande precisão o Kps destes hidróxidos utilizando a metodologia proposta, o que é promissor e encorajador para trabalhos futuros. Estudou-se também a eletrodeposição dos íons Fe3+, Cu2+ e Mn2+ in situ com a RMN-DT. A eletrodeposição tem número considerável de aplicações, tanto na pesquisa, quanto na indústria. E a possibilidade de se monitorar a retirada de íons metálicos sem que esta tenha de ser parada e, além disto, não precisando controlar a viscosidade da solução ou adicionar indicadores químicos é muito interessante. Para este estudo in situ, foram construídas e testadas duas células eletroquímicas, realizadas voltametrias cíclicas para estudo prévio e, finalmente, a eletrodeposição in situ da das soluções. O melhor resultado obtido foi para o Fe3+, seguido do Cu2+, não sendo possível observar a eletrodeposição do Mn2+.
Titre en anglais
Use of time domain NMR relaxometry to study paramagnetic ions in solution
Mots-clés en anglais
nuclear magnetic resonance
paramagnetic íons
Resumé en anglais
The study of ionic solutions is of great importance to analytical chemistry. In NMR, a significant number of researchers devote themselves to the understanding of the role that paramagnetic ions have on longitudinal (T1) and transverse (T2) relaxation times. However, most of the papers published until today have studied this influences on T1, which is whatsoever more complicated to measure than T2. Therefore, we applied we applied the time domain NMR (TD-NMR) transverse relaxometry to study paramagnetic ions in aqueous solutions. The first application was the determination of the Fe(OH)3, Cu(OH)2 and Mn(OH)2 solubility product constants (Ksp). The knowledge of these constants is of industrial and academic interest. Moreover, Ksp is studied as a direct consequence of chemical equilibrium, which prejudices the acquisition of a deeper understanding to the problematic. Thus, use of TD-NMR to study Ksp is a new approach to the already done, with great teaching potential. It was possible to almost precisely determine the Ksp hydroxide values through the proposed methodology, which is promising and encouraging to future studies. It was also explored Fe3+, Cu2+ and Mn2+ electrochemical-NMR in situ experiments. Electrodeposition has a considerable number of applications in research as in industry. And the possibility to monitor the withdrawn of paramagnetic ions from the solution without ceasing the reaction and without the worry of solution viscosity or the need to add chemical indicator is really interesting. To the in situ study two electrochemical cells were built and tested, cyclic voltammetry and amperometric deposition were made. The best result was for iron, followed by copper. Manganese electrodeposition wasn't observed.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
PauloFalcoCobraR.pdf (2.05 Mbytes)
Date de Publication
2012-11-05
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.