Disertación de Maestría
DOI
https://doi.org/10.11606/D.75.2012.tde-19102012-161738
Documento
Autor
Nombre completo
Paulo Falco Cobra
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2012
Director
Tribunal
Colnago, Luiz Alberto (Presidente)
Azevêdo, Eduardo Ribeiro de
Plepis, Ana Maria de Guzzi
Título en portugués
Uso da relaxometria de RMN no domínio do tempo para estudo de íons paramagnéticos em solução
Palabras clave en portugués
íons paramagnéticos
ressonância magnética nuclear
Resumen en portugués
O estudo de soluções iônicas tem grande importância na química analítica. Na RMN, vários pesquisadores se dedicam ao entendimento do papel de íons paramagnéticos nos tempos de relaxação longitudinal (T1) e transversal (T2). A maioria dos trabalhos nesta área se dedicou ao estudo destas influências no T1, que é uma medida bem mais lenta do que a de T2. Assim, neste trabalho se estudou as implicações da relaxometria de T2 por RMN no domínio do tempo (RMN-DT) em soluções de íons paramagnéticos. A partir deste estudo, demonstrou-se a correlação linear entre a taxa de relaxação transversal (1/T2) e a concentração dos íons paramagnéticos. Com isso, usou-se esta metodologia na determinação de constantes do produto de solubilidade (Kps) dos hidróxidos Fe(OH)3, Cu(OH)2 e Mn(OH)2. A determinação da constante de solubilidade (Kps) tem grande importância e aplicação em química, principalmente na separação de íons por precipitação. Foi possível determinar com grande precisão o Kps destes hidróxidos utilizando a metodologia proposta, o que é promissor e encorajador para trabalhos futuros. Estudou-se também a eletrodeposição dos íons Fe3+, Cu2+ e Mn2+ in situ com a RMN-DT. A eletrodeposição tem número considerável de aplicações, tanto na pesquisa, quanto na indústria. E a possibilidade de se monitorar a retirada de íons metálicos sem que esta tenha de ser parada e, além disto, não precisando controlar a viscosidade da solução ou adicionar indicadores químicos é muito interessante. Para este estudo in situ, foram construídas e testadas duas células eletroquímicas, realizadas voltametrias cíclicas para estudo prévio e, finalmente, a eletrodeposição in situ da das soluções. O melhor resultado obtido foi para o Fe3+, seguido do Cu2+, não sendo possível observar a eletrodeposição do Mn2+.
Título en inglés
Use of time domain NMR relaxometry to study paramagnetic ions in solution
Palabras clave en inglés
nuclear magnetic resonance
paramagnetic íons
Resumen en inglés
The study of ionic solutions is of great importance to analytical chemistry. In NMR, a significant number of researchers devote themselves to the understanding of the role that paramagnetic ions have on longitudinal (T1) and transverse (T2) relaxation times. However, most of the papers published until today have studied this influences on T1, which is whatsoever more complicated to measure than T2. Therefore, we applied we applied the time domain NMR (TD-NMR) transverse relaxometry to study paramagnetic ions in aqueous solutions. The first application was the determination of the Fe(OH)3, Cu(OH)2 and Mn(OH)2 solubility product constants (Ksp). The knowledge of these constants is of industrial and academic interest. Moreover, Ksp is studied as a direct consequence of chemical equilibrium, which prejudices the acquisition of a deeper understanding to the problematic. Thus, use of TD-NMR to study Ksp is a new approach to the already done, with great teaching potential. It was possible to almost precisely determine the Ksp hydroxide values through the proposed methodology, which is promising and encouraging to future studies. It was also explored Fe3+, Cu2+ and Mn2+ electrochemical-NMR in situ experiments. Electrodeposition has a considerable number of applications in research as in industry. And the possibility to monitor the withdrawn of paramagnetic ions from the solution without ceasing the reaction and without the worry of solution viscosity or the need to add chemical indicator is really interesting. To the in situ study two electrochemical cells were built and tested, cyclic voltammetry and amperometric deposition were made. The best result was for iron, followed by copper. Manganese electrodeposition wasn't observed.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
PauloFalcoCobraR.pdf (2.05 Mbytes)