Tesis Doctoral
DOI
https://doi.org/10.11606/T.75.2023.tde-11122023-123416
Documento
Autor
Nombre completo
Cleyton Nascimento Makara
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2023
Director
Tribunal
Carrilho, Emanuel (Presidente)
Anibal, Fernanda de Freitas
Bernardi, Juliana Cancino
Coltro, Wendell Karlos Tomazelli
Paixão, Thiago Regis Longo Cesar da
Título en portugués
Desenvolvimento de um dispositivo microfluídico baseado em papel (µPAD) para diagnóstico rápido em amostras de sangue no local de atendimento (POC)
Palabras clave en portugués
µPAD
análise de imagem
anemia
ferritina
hemoglobina
microfluídica
nanopartículas de ouro
papel
sangue
saúde
Resumen en portugués
Este trabalho foi desenvolvido com objetivo de monitorar a prevalência de anemia na população, baseado nos dispositivos analíticos microfluídicos de papel (µPAD), oferecendo uma ferramenta de diagnóstico rápida e barata, inestimável para tomadas de decisão. Seu funcionamento consiste na aplicação de uma gota de sangue em um pedaço de papel filtro, onde uma fotografia é retirada com smartphone e a imagem tratada com software fornece resultados de hemoglobina, hematócrito e ferritina. Para minimizar erros provenientes da etapa de aquisição de imagem, propusemos a construção de um suporte em acrílico para o smartphone, reduzindo assim o desvio padrão dos resultados, protegendo o operador de possível contaminação do material coletado. A impressão de região colorida no interior do suporte de acrílico apresentou uma alternativa atraente para a calibração das cores decorrente da câmera de diferentes smartphones. Os resultados de hematócrito e hemoglobina apresentaram correlação de 56,85 % e 55,48 % respectivamente, com 207 voluntários do gênero masculino e feminino, compreendendo idades entre 17 e 62 anos, utilizando variáveis de área da imagem, intensidade de cor e gênero. Os dados analisados apresentaram-se em consonância aos obtidos pelo equipamento CompoLab TM do HemoBanco. O método proposto para obtenção de plasma no interior do µPAD de maneira passiva para quantificação de ferritina, apresentou reprodutibilidade e ausência de hemólise, com plasma límpido. Este método para obtenção de plasma em µPAD poderá ser empregado para quantificação de outros analitos de interesse no sangue. A reação com AuNPs para quantificação de ferritina apresentou alteração visual de cor na faixa sérica humana entre 30 e 300 ng/mL, testado com padrão de ferritina em solução PBS. O método proposto para diagnosticar anemia com a quantificação de hemoglobina e hematócrito mostrou-se rápido, simples e exato. Espera-se que o contínuo desenvolvimento de µPADs de baixo custo na área da saúde, integrado aos sistemas e políticas de saúde do governo, auxilie no seu planejamento e que chegue àqueles que o necessitem, contribuindo com a saúde da população e seu desenvolvimento.
Título en inglés
Development of a paper-based microfluidic device (µPAD) for rapid on-site diagnosis in blood samples (POC)
Palabras clave en inglés
µPAD
anemia
blood
ferritin
gold nanoparticles
health
hemoglobin
image analysis
microfluidic
paper
Resumen en inglés
This work was developed with the aim of monitoring the prevalence of anemia in the population, based on microfluidic paper analytical devices (µPADs), offering a rapid and inexpensive diagnostic tool invaluable for decision-making. Its operation involves applying a drop of blood to a piece of filter paper, where a photograph is taken with a smartphone and the image is processed with software to provide results for hemoglobin, hematocrit, and ferritin. To minimize errors from the image acquisition stage, we proposed the construction of an acrylic support for the smartphone, thus reducing the standard deviation of results and protecting the operator from possible contamination of the collected material. The printing of a colored region inside the acrylic support provided an attractive alternative for color calibration resulting from different smartphones' cameras. Hematocrit and hemoglobin results showed correlations of 56,85% and 55,48%, respectively, with 207 male and female volunteers aged between 17 and 62 years, using variables such as image area, color intensity, and gender. The analyzed data were in line with those obtained by the CompoLab TM equipment from HemoBanco. The proposed method for passive plasma collection inside the µPAD for ferritin quantification demonstrated reproducibility and absence of hemolysis, yielding clear plasma. This method for plasma collection in µPAD could be employed for quantifying other analytes of interest in the blood. The reaction with AuNPs for ferritin quantification showed a visual color change in the human serum range between 30 and 300 ng/mL, tested with a ferritin standard in PBS solution. The proposed method for diagnosing anemia through the quantification of hemoglobin and hematocrit proved to be fast, simple, and accurate. It is hoped that the continued development of low-cost µPADs in healthcare, integrated into government health systems and policies, will assist in planning and reach those in need, contributing to the health and development of the population.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-12-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.