Tesis Doctoral
DOI
https://doi.org/10.11606/T.75.2024.tde-03042024-080310
Documento
Autor
Nombre completo
Desirée Tamara Scheidt
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2024
Director
Tribunal
Carrilho, Emanuel (Presidente)
Barud, Hernane da Silva
Janegitz, Bruno Campos
Legnani, Cristiano
Muñoz, Rodrigo Alejandro Abarza
Título en portugués
Sensores eletroquímicos à base de grafeno obtidos pela indução a laser da celulose bacteriana
Palabras clave en portugués
celulose bacteriana
eletroanálises
ePAD
grafeno induzido à laser
Resumen en portugués
A eletroquímica, aliada a plataformas sustentáveis como papel e celulose bacteriana, viabiliza dispositivos portáteis, econômicos e de fácil operação. Entretanto, as abordagens convencionais para desenvolver dispositivos analíticos eletroquímicos baseados em papel frequentemente se mostram complexas, com baixa reprodutibilidade e dificuldades de escalonamento. Propomos aqui uma metodologia inovadora, prática e de uma única etapa para a geração de grafeno induzido por laser em superfícies de celulose bacteriana. Esta técnica elimina a dependência de reagentes químicos e de condições ambientais específicas para o desenvolvimento de sensores eletroquímicos. O método de produção, que inclui a aplicação de laser CO2 e a funcionalização do substrato, foi otimizado. O grafeno obtido foi extensivamente caracterizado, destacando-se por seu elevado grau de grafitização, porosidade e elevada área superficial específica (300 mm2). A técnica de gravação a laser, de forma direta e eficiente, simplifica a fabricação de eletrodos em larga escala, garantindo uma notável consistência dos sinais potenciométricos, com mínima variação entre medições (3,41%) e entre dispositivos (1,09%). A eficácia do sensor recém-desenvolvido foi avaliada para a análise quantitativa do acetaminofeno. Esta avaliação revelou a alta precisão do sensor na determinação desse medicamento, evidenciada pelos limites de detecção e quantificação de 1,65 e 5,00 µmol L-1, respectivamente. Adicionalmente, o sensor demonstrou grande potencial para uso em amostras biológicas, especificamente em urina, com taxas de recuperação do acetaminofeno variando entre 93% e 114%. Esses resultados, aliados à facilidade de acesso aos materiais, à simplicidade dos equipamentos empregados e às notáveis propriedades do material obtido, destacam este método como uma abordagem inovadora e sustentável para a fabricação e aplicação de sensores eletroquímicos baseados em papel.
Título en inglés
Electrochemical sensors based on graphene obtained by laser induction of bacterial cellulose
Palabras clave en inglés
bacterial cellulose
electroanalysis
ePAD
laser induced graphene
Resumen en inglés
Electrochemistry, combined with sustainable platforms like paper and bacterial cellulose, enables portable, economical, and user-friendly devices. However, conventional approaches to developing paper-based electrochemical analytical devices often prove complex, poorly reproducible and challenging to scale. We present an innovative, practical, and single-step methodology for the generation of laser-induced graphene on bacterial cellulose surfaces, eliminating chemical reagents and controlled condition needs. The production method, which includes applying of CO2 laser and substrate functionalization, was optimized. The obtained graphene was extensively characterized, notable for its high degree of graphitization, porosity, and specific surface area (300 mm2). The direct and efficient laser engraving technique simplifies the fabrication of electrodes on a large scale, ensuring remarkable consistency of potentiometric signals, with minimal variation between measurements (3.41%) and between devices (1.09%). The efficacy of the newly developed sensor was evaluated for the quantitative analysis of acetaminophen. This evaluation revealed the sensor's high precision in determining this drug, evidenced by detection and quantification limits of 1.65 and 5.00 µmol L-1, respectively. Additionally, the sensor demonstrated enormous potential for use in biological samples, specifically in urine, with acetaminophen recovery rates ranging from 93% to 114%. These results, coupled with the ease of access to materials, the simplicity of the equipment used, and the remarkable properties of the obtained material, highlight this method as an innovative and sustainable manufacturing and applying paper-based electrochemical sensors.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2024-04-03
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.