• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.74.2020.tde-18052021-142742
Documento
Autor
Nombre completo
Alois Foltran Müller
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Pirassununga, 2020
Director
Tribunal
Freitas, Silvio Henrique de (Presidente)
Dias, Luís Gustavo Gosuen Gonçalves
Rigo, Eliana Cristina da Silva
Título en portugués
Viabilidade dos fios de poliamida nacional e importado como alternativa para a técnica de TightRope modificada no tratamento de insuficiência do ligamento cruzado cranial espontâneo em cães
Palabras clave en portugués
Biomaterial
Limite elástico
Macro e microanálise
Náilon
Resumen en portugués
O ligamento cruzado cranial é um dos principais responsáveis pela estabilidade da articulação femorotibiopatelar. Quando rompido ou lacerado (insuficiente), ele proporciona instabilidade da tíbia em relação ao fêmur, levando à claudicação e, também, à doença articular degenerativa. A técnica de TightRope é um método de estabilização extracapsular que emprega fita ultrapolietileno resistente, com âncoras confeccionadas em titânio, que têm como objetivo anular o movimento de gaveta cranial e de rotação interna da tíbia. A fim de se verificar a viabilidade dos fios de poliamida (náilon) como alternativa à fita de ultrapolietileno, estes foram analisados por meio de ensaios mecânicos de tensão, citotoxicidade indireta, por microscopia eletrônica de varredura (MEV) e pela espectroscopia no infravermelho (IV). Os fios testados foram acomodados em um dispositivo, desenvolvido para esta finalidade, e esterilizado em autoclave à 121°C por 15 minutos. Os resultados revelaram que o dispositivo de acomodação, se mostrou eficiente na manutenção do comprimento e diâmetro dos fios autoclavados. Por meio dos ensaios mecânicos de tensão foi possível obter o limite elástico dos fios e assim relacionar o seu diâmetro com o peso do cão com ILCCr. A espectroscopia no IV não indicou alteração molecular da poliamida e o teste de citotoxicidade indireta revelou que o fio de poliamida importado é citotóxico a linhagem celular testada e por isso seu uso in vivo não é indicado. Portanto, o fio de náilon de pesca nacional autoclavado é uma alternativa viável para o tratamento da ILCCr, de baixo custo, fácil aquisição e que pode ser utilizado para outros tipos de cirurgias articulares e em áreas da medicina veterinária que necessitem de fios mais resistentes.
Título en inglés
Viability of national and imported polyamide threads as an alternative to the modified TightRope technique for the treatment of spontaneous cranial cruciate ligament insufficiency in dogs
Palabras clave en inglés
Biomaterial
Elastic limit
Macro and microanalysis
Nylon
Resumen en inglés
The cranial cruciate ligament is one of the main responsible for the femorotibiopatellar joint stability. When ruptured or lacerated (insufficient), it provides instability of the tibia relative to the femur, leading to lameness and also to degenerative joint disease. The TightRope is an extracapsular stabilization technique in which a resistant ultrapolethylene tape, secured with endobuttons made of titanium, aims to prevent the cranial drawer movement and the tibial internal rotation. To check the polyamide (nylon) threads viability as an alternative to the ultrapolethylene tape, these were analyzed employing mechanical stress tests, indirect cytotoxicity assessment, scanning electron microscopy (SEM), and by infrared spectroscopy (IR). The tested threads were accommodated in a device, developed for this purpose, and steam-sterilized at 120°C for 15 minutes. The results revealed that the accommodation device created was efficient in maintaining the length and diameter of the steam-sterilized threads. Through the mechanical stress tests, it was possible to obtain the threads elastic limits and thus to relate its diameter to the weight of the dog with cranial cruciate ligament insufficiency (CCLI). The IR spectroscopy did not show polyamide molecular alteration. The indirect cytotoxicity test revealed that the imported polyamide is cytotoxic to the cell line tested and, therefore, its use is not recommended in vivo, despite the favorable mechanical test results. Thus, the national steam-sterilized nylon fishing line is a viable alternative for the CCLI treatment, has low cost, easy acquisition, and can be used in other types of articular surgeries and in veterinary fields that require a more resistant suture.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
ME7145860COR.pdf (2.24 Mbytes)
Fecha de Publicación
2021-05-18
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.