• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.74.2020.tde-18052021-142742
Document
Author
Full name
Alois Foltran Müller
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Pirassununga, 2020
Supervisor
Committee
Freitas, Silvio Henrique de (President)
Dias, Luís Gustavo Gosuen Gonçalves
Rigo, Eliana Cristina da Silva
Title in Portuguese
Viabilidade dos fios de poliamida nacional e importado como alternativa para a técnica de TightRope modificada no tratamento de insuficiência do ligamento cruzado cranial espontâneo em cães
Keywords in Portuguese
Biomaterial
Limite elástico
Macro e microanálise
Náilon
Abstract in Portuguese
O ligamento cruzado cranial é um dos principais responsáveis pela estabilidade da articulação femorotibiopatelar. Quando rompido ou lacerado (insuficiente), ele proporciona instabilidade da tíbia em relação ao fêmur, levando à claudicação e, também, à doença articular degenerativa. A técnica de TightRope é um método de estabilização extracapsular que emprega fita ultrapolietileno resistente, com âncoras confeccionadas em titânio, que têm como objetivo anular o movimento de gaveta cranial e de rotação interna da tíbia. A fim de se verificar a viabilidade dos fios de poliamida (náilon) como alternativa à fita de ultrapolietileno, estes foram analisados por meio de ensaios mecânicos de tensão, citotoxicidade indireta, por microscopia eletrônica de varredura (MEV) e pela espectroscopia no infravermelho (IV). Os fios testados foram acomodados em um dispositivo, desenvolvido para esta finalidade, e esterilizado em autoclave à 121°C por 15 minutos. Os resultados revelaram que o dispositivo de acomodação, se mostrou eficiente na manutenção do comprimento e diâmetro dos fios autoclavados. Por meio dos ensaios mecânicos de tensão foi possível obter o limite elástico dos fios e assim relacionar o seu diâmetro com o peso do cão com ILCCr. A espectroscopia no IV não indicou alteração molecular da poliamida e o teste de citotoxicidade indireta revelou que o fio de poliamida importado é citotóxico a linhagem celular testada e por isso seu uso in vivo não é indicado. Portanto, o fio de náilon de pesca nacional autoclavado é uma alternativa viável para o tratamento da ILCCr, de baixo custo, fácil aquisição e que pode ser utilizado para outros tipos de cirurgias articulares e em áreas da medicina veterinária que necessitem de fios mais resistentes.
Title in English
Viability of national and imported polyamide threads as an alternative to the modified TightRope technique for the treatment of spontaneous cranial cruciate ligament insufficiency in dogs
Keywords in English
Biomaterial
Elastic limit
Macro and microanalysis
Nylon
Abstract in English
The cranial cruciate ligament is one of the main responsible for the femorotibiopatellar joint stability. When ruptured or lacerated (insufficient), it provides instability of the tibia relative to the femur, leading to lameness and also to degenerative joint disease. The TightRope is an extracapsular stabilization technique in which a resistant ultrapolethylene tape, secured with endobuttons made of titanium, aims to prevent the cranial drawer movement and the tibial internal rotation. To check the polyamide (nylon) threads viability as an alternative to the ultrapolethylene tape, these were analyzed employing mechanical stress tests, indirect cytotoxicity assessment, scanning electron microscopy (SEM), and by infrared spectroscopy (IR). The tested threads were accommodated in a device, developed for this purpose, and steam-sterilized at 120°C for 15 minutes. The results revealed that the accommodation device created was efficient in maintaining the length and diameter of the steam-sterilized threads. Through the mechanical stress tests, it was possible to obtain the threads elastic limits and thus to relate its diameter to the weight of the dog with cranial cruciate ligament insufficiency (CCLI). The IR spectroscopy did not show polyamide molecular alteration. The indirect cytotoxicity test revealed that the imported polyamide is cytotoxic to the cell line tested and, therefore, its use is not recommended in vivo, despite the favorable mechanical test results. Thus, the national steam-sterilized nylon fishing line is a viable alternative for the CCLI treatment, has low cost, easy acquisition, and can be used in other types of articular surgeries and in veterinary fields that require a more resistant suture.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
ME7145860COR.pdf (2.24 Mbytes)
Publishing Date
2021-05-18
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.