Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.7.2019.tde-23022021-093947
Document
Auteur
Nom complet
Ana Tércia Barijan
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2019
Directeur
Jury
Graziano, Kazuko Uchikawa (Président)
Barbosa, Maria Clara Padoveze Fonseca
Bruna, Camila Quartim de Moraes
Turrini, Ruth Natalia Teresa
Titre en portugais
Avaliação da segurança da esterilização por peróxido de hidrogênio vaporizado nas práticas atuais do centro de material e esterilização
Mots-clés en portugais
Enfermagem em centro de material e esterilização
Esterilização a baixa temperatura
Esterilização peróxido de hidrogênio vaporizado
Indicadores biológicos
Segurança do paciente
Resumé en portugais
Introdução: O recente avanço das técnicas cirúrgicas demandou a utilização de métodos de esterilização a baixa temperatura, tal como o peróxido de hidrogênio vaporizado (VH2O2), para possibilitar a esterilização de produtos para saúde (PPS) termossensíveis. Embora amplamente utilizado nos Centros de Material e Esterilização (CME), os problemas relacionados à esta tecnologia são muitos, tais como: baixa difusibilidade do VH2O2, ausência de normas construtivas e de validação, limitação das tecnologias para medir a concentração do agente esterilizante, validação e monitoramento dos ciclos, além de práticas inadequadas de carregamento e esterilização de PPS. Objetivo: Avaliar, por meio de indicadores físicos (IF) e biológicos (IB), se as práticas atuais do CME, na escolha das cargas e do carregamento, interferem na segurança dos esterilizadores de VH2O2: Sterrad® 100S ciclo curto, Sterrad® 100NX ciclo padrão e Vpro® Max ciclo sem lúmen. Método: Pesquisa de campo, exploratória e descritiva, realizada em hospitais que utilizam os equipamentos supracitados na rotina. Os dados foram coletados após aprovação do Comitê de Ética e Pesquisa e autorização dos hospitais participantes. Foram avaliados três esterilizadores de cada modelo de CMEs distintos, sendo que a escolha dos ciclos para coleta dos dados deu-se pela maior criticidade e frequência de utilização nos locais de estudo. Os IB foram posicionados, unitariamente, em envelopes duplos de Tyvek® (considerados pacote-teste), com fechamento por selagem térmica. Em cada esterilizador, foi realizado um ensaio vazio em meio ciclo, com três pacotes-testes nas seguintes posições: superior/anterior; superior/centro e inferior/posterior. Sequencialmente, foram realizados ensaios com a mesma carga em triplicata, compostos pelos PPS que representam um desafio à rotina, também, em meio ciclo. Internamente, adicionaram-se IB, além de dois pacotes-testes posicionados na parte superior/anterior e inferior /posterior, sendo o primeiro colocado no ponto mais próximo da entrada do agente esterilizante, e o segundo colocado no ponto mais distante. Resultados: do total de 9 ensaios com carga para cada modelo de esterilizador, obtemos IB positivos em 22% dos ensaios do modelo 100S, 33% no modelo 100NX e 100% no modelo V-pro. Os IB positivos foram relacionados à sobreposição de pacotes, à presença de tapete imantado, às bandejas de acondicionamento sem instrução de uso do fabricante (IUF) para o método e, principalmente, à difusibilidade do VH2O2 prejudicada em pontos mais distantes da entrada do VH2O2 na câmara de esterilização. Outras hipóteses que podem ter contribuído para o resultado foram a falta de IUF dos PPSs para o método e o uso de massa adicional que consome o VH2O2. Não foi possível correlacionar os resultados dos IB positivos aos parâmetros físicos do esterilizador, bem como ao total de peso da carga. Conclusão: O presente estudo pode afirmar que as cargas e o carregamento interferem na segurança dos esterilizadores por VH2O2. As IUF validadas dos esterilizadores, dos PPSs, dos sistemas de barreira estéril e das bandejas de acondicionamento devem ser respeitadas, como também a qualificação dos equipamentos com carga que representem um desafio da rotina utilizando-se IB em meio ciclo. Este procedimento pode detectar a insuficiência de exposição dos PPSs ao agente esterilizante para atender o Nível de Segurança de Esterilidade (SAL - Sterility Assurance Level) de 10-6 . Atualmente, o monitoramento de rotina de todos os ciclos com IB é o procedimento mais seguro para este método de esterilização.
Titre en anglais
Safety Assessment of Vaporized Hydrogen Peroxide Sterilization in the Current Practices of Central Sterile Service Departments
Mots-clés en anglais
Biological indicators
Nursing at sterile & materials processing centers
Patient safety
Sterilization at low temperature
Sterilization by vaporized hydrogen peroxide
Resumé en anglais
Introduction: The recent advances in surgical techniques have required the use of low- temperature sterilization methods, such as vaporized hydrogen peroxide (VH2O2), to enable the sterilization of thermo-sensitive health care products. Although widely applied in Central Sterile Service Departments (CSSD), problems related to this technology are many such as: low diffusivity, lack of constructive and validation standards, technology limitation to measure the concentration of the sterilizing agent, cycle validation and monitoring, as well as inadequate loading and sterilization practices for health care products. Objective: Evaluating, through physical (PI) and biological (BI) indicators, whether the current practices of Central Sterile Service Departments, when choosing the load and the loading processes, interfere with the safety of VH2O2 sterilizers: Sterrad® 100S short cycle, Sterrad® 100NX standard cycle and Vpro® Max lumenless cycle. Method: Field, exploratory and descriptive research study performed in hospitals that use the aforementioned equipment in the working routine. Data were collected after approval by the Research Ethics Committee and authorization of the participating hospitals. Three sterilizers from each model and from different CSSD were evaluated, and the choice of cycles for data collection followed the criticality and frequency of use in the study sites. The BIs were unitarily positioned in double-Tyvek® (test-package) envelopes, with heat-sealing closure. In each sterilizer, a half-cycle no-loading test was performed, with three testing-packages in the following positions: upper/anterior; upper/center and lower/posterior. Subsequently, triplicate assays were performed with the same load, containing health care products that represent a routine challenge, also, in half cycle. BIs were added internally, in addition to two testing-packages, positioned in the upper/anterior and inferior/posterior area, the first placed at the point closest to the entrance of the sterilizing agent in the chamber, and the second at the farthest point. Results: For total of 9 assays with load from each sterilizers model, positive BIs 22% on assays in the 100S model test, 33% in the 100NX model and 100% in the V-pro model. The positive BIs were related to package overlapping; presence of magnetic mat; packaging trays, without the recommendations of the equipment manufacturers; and impaired diffusion of the VH2O2 sterilizing agent in the sterilization chamber, especially at points distant from the agent entrance. Other hypotheses that may have contributed to the result were the lack of IFU of the health care products for the method, as well as the use of additional mass consuming VH2O2. It was not possible to correlate the positive BI results to the physical parameters of the sterilizer, as well as to the total weight of the load. Conclusion: The current research study can conclude that the loads and the loading interfere in the safety of the sterilizers by VH2O2. The validated instructions for use of sterilizers manufacturers, health care products, sterile barrier systems and packaging trays must be respected, as well as the qualification of loading equipment, representing a challenge to the routine using BI in half cycle. This procedure can detect the insufficient exposure of health care products to the sterilizing agent to meet the Sterility Assurance Level (SAL) of 10-6 . Currently, routine monitoring of all cycles with BIs is the safest procedure for this sterilization method.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Ana_TBarijan.pdf (4.31 Mbytes)
Date de Publication
2021-02-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.