• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.64.2013.tde-22052013-094046
Documento
Autor
Nombre completo
Taciana Figueiredo Gomes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2013
Director
Tribunal
Zagatto, Elias Ayres Guidetti (Presidente)
Nogueira, Ana Rita de Araujo
Raimundo Junior, Ivo Milton
Título en portugués
Determinação espectrofotométrica de sulfato em águas de chuva em um sistema de análises químicas em fluxo envolvendo troca-iônica
Palabras clave en portugués
Análises químicas por injeção em fluxo
Espectrofotometria UV-Vis
Resina de troca iônica
Sulfato
Resumen en portugués
Um sistema de análises químicas por injeção em fluxo foi desenvolvido e aplicado à determinação espectrofotométrica de baixas concentrações de sulfato em águas de chuva. O método explora a reação de deslocamento entre o ânion sulfato e o complexo dimetilsulfonazo (III) de bário, Ba-DMSA, com consequente formação do sal pouco solúvel BaSO4. A solução com o complexo Ba-DMSA apresenta alta absortividade molar a 656 nm, e uma diminuição pronunciada na absorbância ocorre na presença de sulfato. Desta forma, o sinal analítico é registrado como pico invertido proporcional à concentração de sulfato na amostra. A presença de altas concentrações de dimetilsulfóxido, DMSO, no reagente favorece a intensidade do sinal analítico, por coordenar as moléculas de água, melhorando a sensibilidade do método. A utilização do tensoativo dodecilsulfato de sódio, SDS, determina também uma melhoria considerável na sensibilidade analítica, pois sua presença no ambiente reacional altera as condições de supersaturação. A sensibilidade e seletividade do procedimento são melhoradas incluindo-se uma etapa de troca iônica em linha, com resina aniônica Dowex 1-X8, para concentração do sulfato e separação dos íons interferentes em potencial. O sistema proposto é robusto e fornece resultados precisos (d.p.r. < 0,01) com frequência analítica de 30 determinações por hora. O consumo de DMSA é de 0,17 'mü'mol por determinação. A curva analítica se apresenta linear até 2,0 mg L-1 SO42- e os limites de detecção e de quantificação foram estimados em 0,01 mg L-1 SO42- e 0,04 mg L-1 SO42-.
Título en inglés
Spectrophotometric determination of sulphate in rain waters using a flow injection system with ion-exchange
Palabras clave en inglés
Flow injection analysis
Ion exchange resin
Sulfate
UV-Vis spectrophotometry
Resumen en inglés
A flow injection system was developed and applied to the spectrophotometric determination of low concentrations of sulphate in rain waters. The method exploits the displacement reaction involving the sulphate anion and the barium dimethylsulfonazo (III) complex, Ba-DMSA, with consequent formation of the slightly soluble BaSO4 salt. As the Ba-DMSA solution is characterized by a high molar absorptivity at 656 nm, a pronounced absorbance lessening is observed in the presence of sulphate. The analytical signal is then recorded as an inverted peak proportional to the sulphate content in the sample. Presence of dimethylsulphoxide, DMSO, at high concentrations in the reaction medium leads to an enhancement of the analytical signals, coordinating water molecules, thus improving the sensitivity of the method. Addition of the surfactant sodium dodecylsulphate, SDS, results also in a pronounced improvement in sensitivity, as its presence in the reaction medium alters the supersaturation conditions. The sensitivity and selectivity of the method were improved by including an in-line ion exchange mini-column with the anionic resin Dowex 1-X8 into the manifold, for sulphate concentration and separation from potential interfering ions. The proposed system is robust and provides accurate results (R.S.D. <0.01) at an analytical frequency of 30 determinations per hour. About 0.17 'mü'mol DMSA are consumed per determination. The analytical curve is linear up to 2.0 mg L-1 SO42- and the detection and quantification limits were estimated as 0.01 mg L-1 SO42- and 0.04 mg L-1 SO42-.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2013-05-29
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.