• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.64.2010.tde-08092010-163201
Documento
Autor
Nombre completo
Paula Regina Fortes
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2010
Director
Tribunal
Zagatto, Elias Ayres Guidetti (Presidente)
Angnes, Lucio
Fatibello Filho, Orlando
Gomes Neto, José Anchieta
Pereira Filho, Edenir Rodrigues
Título en portugués
Sistemas de análises químicas em fluxo explorando mecanismos de re-alimentação, calibração multivariada e outras abordagens para melhoria em desempenho
Palabras clave en portugués
Calibração multivariada
Diálise
Mescla turbulenta
Nanocristais Quantum Dots
Sistemas com multi-impulsão
Sistemas de análises por injeção em fluxo
Sistemas inteligentes
Resumen en portugués
Estudos foram conduzidos relativamente ao desempenho dos sistemas de análises em fluxo quando configurados como sistemas inteligentes, associados às técnicas de calibração multivariada ou empregando nanocristais como sensibilizadores. Ainda, melhorias relacionadas às modificações dos fluxos foram avaliadas, especialmente no que se refere à diálise em linha. Neste sentido, foi proposta uma nova estratégia para implementar determinações simultâneas de ferro e vanádio em ligas metálicas envolvendo cinética diferencial. O método baseava-se nas diferentes influências exercidas por Fe2+ e por V4+ na taxa de oxidação de íons iodeto por íons Cr6+ sob condições ácidas. Três diferentes alíquotas de amostra eram inseridas em um fluxo transportador / reagente de KI, confluindo posteriormente com um fluxo de K2Cr2O7. A sobreposição entre as três zonas de amostra estabelecidas resultava em uma zona de amostra complexa com diversos valores de absorbância. Medidas realizadas nos pontos de máximos e minímos do sinal registrado eram mais precisas e continham informações acerca dos diferentes estágios de desenvolvimento da reação e de diferentes condições de concentrações. Em outra estratégia, um sistema MPFS inteligente foi proposto para a determinação turbidimétrica sequencial de sulfato e cloreto em águas naturais. Ambos os métodos foram implementados no mesmo módulo de análises, proporcionando facilidades relativas ao: preparo de amostra em linha; adição de íons sulfato ou cloreto ao meio reacional para melhoria das condições de supersaturação; decisão em tempo real acerca da necessidade ou não da próxima análise. Inicialmente, determinava-se a concentração de cloreto presente na amostra, e este resultado era comparado com um valor pré-determinado. Se este fosse superior, a amostra era analisada novamente visando à determinação de sulfato. Caso contrário, uma nova amostra era analisada. A estratégia resultou em aumento da velocidade analítica e em boas figuras de mérito analítico. Estudos relativos à natureza do fluxo foram conduzidos avaliando-se o desempenho dos fluxos pulsados provenientes de bombas solenóide em relação à eficiência do transporte de massas, dispersão da zona de amostra relacionada com a mudança de sentido do fluxo e eficiência do processo de diálise quando comparados aos fluxos tipicamente laminares. Embora fosse observada a presença de vórtices, o número de Reynolds experimentalmente obtido demonstrou que o fluxo resultante não era turbulento. Porém seu perfil exibia características de mescla turbulenta, melhorando assim o desempenho relativo ao transporte de massas e redução da dispersão da zona de amostra. Entretanto, beneficios relativos a melhorias no processo de diálise foram ausentes devido provavelmente à alta pressão exercida dentre da câmara de diálise, com consequente deformação dos poros da membrana. Nestas situações, um sistema de análises híbrido (com fluxo laminar e mescla turbulenta) seria fortemente recomendado. Finalmente, a implementação de nanocristais quantum dots (QDs) como sensibilizadores em um sistema MPFS envolvendo reação quimioluminescente foi proposta para a determinação de glipizida e gliclazida em formulaçoes farmacêuticas. O método fundamentava-se na oxidação dos íons S2- por Ce4+ em meio ácido. Na presença dos analitos, a intensidade da radiação emitida era inibida. A influência do diâmetro médio dos nanocristais foi avaliada, e os critérios utilizados para o dimensionamento do sistema foram a repetibilidade, a reprodutibilidade e a sensibilidade analítica. Os analitos foram quantificados no mesmo módulo de análises, e boas figuras de mérito analítico foram verificadas. Os resultados obtidos se apresentaram concordantes com aqueles obtidos pela Farmacopéia Britânica
Título en inglés
Flow systems exploiting feed-back mechanisms, multivariate calibration and other strategies for improving the analytical performance
Palabras clave en inglés
Dialysis
Flow injection analysis
Intelligent systems
Multi-pumping flow system
Multivariate calibration
Quantum Dots nanocrystals
Turbulent mixing
Resumen en inglés
Studies focusing on performance of intelligent analytical flow systems, association with multivariate calibration or use of nanocrystals as sensitizers were carried out. Moreover, improvements related to modifications in flow pattern were evaluated with emphasis to in-line dialysis. To this end, a strategy for implementing simultaneous determinations of iron and vanadium in alloys relying on differential kinetics was proposed. The method was based on the influence of Fe2+ and V4+ on the rate of iodide oxidation by Cr6+ under acidic conditions. Three different plugs of the sample were sequentially inserted into an acidic KI reagent carrier stream, and a confluent K2Cr2O7 solution was added downstream. Overlap between the established plugs led to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions were more precise and revealed the different degrees of reaction development. In another strategy, an intelligent MPFS was proposed for sequential turbidimetric determination of sulphate and chloride in natural waters. Both methods were implemented in the same manifold, providing facilities for: in-line sample cleanup; addition of low amounts of sulphate or chloride ions to the reaction medium for improving supersaturation conditions and real-time decision on the need for next assay. The sample was initially run for chloride determination, and the analytical signal was compared with a preset value. If higher, the sample was run again, now for sulphate determination. Otherwise, next sample was assayed. The strategy led to an increased sample throughput and good analytical figures of merit. Studies focusing on the flow pattern were carried out aiming at the evaluation of the influence of the pulsed flows delivered by solenoid pumps in relation to the efficiency of mass transfer, dispersion related to changes in flow direction of the sample zone and dialysis process as compared with typical laminar flow. Although the establishment of vortices were noted, the experimentally obtained Reynolds number showed that a turbulent flow was not established. Its pattern exhibited characteristics which improved the performance due to the enhanced radial mass transport inherent in turbulent mixing. Comparatively to laminar flow, beneficial aspects were noted in relation to sample dispersion and mass transfer. In relation to dialysis efficiency however process the benefits were not noted probably due to the high pressure inside the dialysis chamber, with consequent membrane pore deformation. In this situation, a hybrid flow analysis system (with laminar flow and turbulent mixing) might be recommended. Implementation of quantum dots nanocrystals (QDs NC) as sensitizers in a MPFS with chemiluminometric detection was proposed for the determinations of gliclazide and glipizide in pharmaceutical formulations. The method relied on the oxidation of sulphite by Ce4+ in acidic medium and, in the presence of the analytes, the emitted radiation of the Ce4+-SO3 2--CdTe QDs system was inhibited. Influence of crystal size was investigated, and the criteria for system optimization were the analytical repeatability, reproducibility and sensitivity. Both analytes were quantified in the same manifold, resulting in good analytical figures of merit. The results were in fairly good agreement with those obtained by the British Pharmacopoeia reference method
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Tese_FortesPR.pdf (9.32 Mbytes)
Fecha de Publicación
2010-09-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.