• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.64.2014.tde-03112014-150442
Document
Author
Full name
Andressa Adame
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Piracicaba, 2014
Supervisor
Committee
Rocha, Fabio Rodrigo Piovezani (President)
Masini, Jorge Cesar
Fatibello Filho, Orlando
Title in Portuguese
Sistema de análises em fluxo empregando multicomutação para avaliação de toxicidade aguda com Vibrio fischeri
Keywords in Portuguese
Análises em fluxo
Diluições em Linha
Ecotoxicidade
Multi-impulsão
Multicomutação
Poluentes emergentes
Abstract in Portuguese
Um sistema de análises em fluxo com multicomutação foi desenvolvido para a mecanização do bioensaio de toxicidade aguda com a bactéria Vibrio fischeri, o qual é baseado na diminuição da luminescência bacteriana causada por espécies tóxicas.Microbombas solenoide foram utilizadas para melhorar as condições de mistura, permitindo também que diluições fossem realizadas em linha com a alteração do volume de amostra e a sobreposição parcial entre a zona da amostra e a suspensão bacteriana. Uma cela de fluxo em espiral, posicionada na janela de emissão de um espectrofluorímetro, foi empregada para as medidas de luminescência e um banho de água construído em laboratório, baseado no efeito Peltier, foi utilizado para manter a temperatura do bioensaio em (13,0±0,1) °C. Um pequeno volume da suspensão bacteriana (120 ?L) foi selecionado visando minimizar o consumo e, consequentemente, os custos do ensaio. O tempo de contato entre a suspensão bacteriana e a amostra foi reduzido para 5 min para aumentar a frequência de amostragem e evitar a atenuação da luminescência devido ao tempo de vida curto das bactérias. Os valores de CE50 para os controles positivos foram estimados em 2,5 ± 0,7, 2,0 ± 0,5 e 10 ± 4 mg L-1 para o Zn(II), Cu(II), e Cr(VI), respectivamente, sendo concordantes com os valores da literatura. Os valores de CE50 para alguns poluentes emergentes (parabenos, cafeína, acetaminofeno, diclofenaco e ácido salicílico) concordaram com os obtidos utilizando o kit comercial BioTox(TM), realizado em micro placa, a nível de confiança de 95 %. Os coeficientes de variação foram estimados em 2,4 e 2 % (n = 10), na ausência e na presença de 0,6 mg L-1 de Zn(II), respectivamente. O sistema de análises em fluxo proposto é, então, uma alternativa simples, rápida, robusta e precisa para a determinação da toxicidade aguda utilizando pequenos volumes de amostra e suspensão bacteriana. Além disso, o sistema apresenta vantagens em comparação com os bioensaios em batelada e em fluxo, tais como ajuste de salinidade e diluições das amostras em linha e a determinação da cinética de toxicidade das espécies químicas
Title in English
A multicommuted flow-based system for acute toxicity evaluation with Vibrio fischeri
Keywords in English
Ecotoxicity
Emerging pollutants
Flow analysis
In-line dilutions
Multi-pumping
Multicommutation
Abstract in English
A multicommuted flow system was developed for automation of the acute toxicity bioassay using Vibrio fischeri bacteria, which exploits the decrease of the bacterial luminescence caused by toxic species. Solenoid micro-pumps were employed to improve mixing conditions and to perform on-line dilutions of the tested compounds by changing the sample volume and exploiting the partial overlap between sample zone and the bacterial suspension. A spiral flow cell, placed at the emission window of a spectrofluorimeter, was employed for signal measurement and a lab-made water bath based on the Peltier effect was used for maintain the temperature of the bioassay at (13.0±0.1) oC. A low volume of the bacterial suspension (120 ?L) was selected in order to minimize its consumption and, consequently, the costs of the assay. The contact time between bacterial suspension and sample was reduced to 5 min to increase the sampling rate and to avoid luminescence fading due to the bacteria short lifetime. EC50 values for positive controls were estimated as 2.5 ± 0.7, 2.0 ± 0.5 and 10 ± 4 for Zn(II), Cu(II), and Cr(VI), respectively, being in agreement with literature values. The EC50 values for some emerging pollutants (parabens, caffeine, acetaminophen, diclofenac and salicylic acid) agreed with those obtained from commercial BioTox(TM) kit performed in micro plate at the 95% confidence level. The coefficients of variation were estimated as 2.4 and 2 % (n=10), in the absence and presence of 0.6 mg L-1 Zn(II), respectively. The proposed flow system is then a simple, fast, robust and accurate alternative for acute toxicity determination, using low sample and bacterial suspension volumes. Furthermore, the system presents advantages in comparison to batch and previous flow-based bioassays, such as the achievement of in-line salinity adjustment and sample dilutions, and the determination of toxicity kinetic for every assayed chemical species
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
AndressaAdame_Revisada.pdf (1,000.68 Kbytes)
Publishing Date
2014-12-01
 
WARNING: The material described below relates to works resulting from this thesis or dissertation. The contents of these works are the author's responsibility.
  • ADAME, A., e ROCHA, F. R. P. A multi-pumping flow system for acute toxicity bioassay using the Vibrio fischeri bacteria [doi:10.1039/c4ay00789a]. Analytical Methods [online], 2014, vol. 6, p. 7367-7373.
  • ADAME, A., e ROCHA, F. R. P. A multicommuted flow-based system for acute toxicity bioassay using Vibrio fischeri bacteria. In 18th International Conference on flow Analysis, Porto-Portugal, 2013. 18th International Conference on flow Analysis., 2013. Resumo.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.