• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.64.2020.tde-19112021-144916
Documento
Autor
Nombre completo
Rafael Giovanini de Lima
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Piracicaba, 2020
Director
Tribunal
Carvalho, Hudson Wallace Pereira de (Presidente)
Barbosa, Renata de Faria
Parreira, Paulo Sérgio
Título en portugués
Alinhamento, programação e comissionamento de um sistema de fluorescência de raios X em regime de reflexão total (TXRF) sob vácuo e automático para aplicação em pesquisas agropecuárias e ambientais
Palabras clave en portugués
Amostras
Análise elementar
Fluorescência de raios X
Fluorescência de raios X por Reflexão Total
Instrumentação (Física)
Resumen en portugués
A avaliação elementar dos constituintes de uma amostra tem grande importância nas ciências agrárias e ambientais. Essas análises podem ser realizadas por diversos métodos e equipamentos. Nesse contexto, a técnica de fluorescência de raios X por reflexão total (TXRF) tem se consolidado devido aos limites de detecção na ordem g L-1 ou g kg-1, uma ampla faixa de resposta linear, sua aplicabilidade a elementos com Z>11, forma de análise não destrutiva, uma diminuta quantidade de amostra e baixo custo operacional. Esse projeto de pesquisa propôs a montagem e comissionamento de um sistema de TXRF com tubo de raios X de alta potência e trocador automático de amostras. Como resultado, a execução desse projeto disponibiliza para a comunidade científica uma ferramenta alternativa às convencionais técnicas analíticas. Esse texto explica detalhadamente os processos de montagem do equipamento, os ajustes das partes moveis - como o monocromador e o substrato refletor -, e os experimentos desenvolvidos. Como validação do equipamento, foram construídas curvas de calibração para amostras líquidas, tecidos vegetais e solos. Análises líquidas tiveram limite de detecção de: 22,3 g L-1 para Fe; 14,7 g L-1 para Ga; e 14,3 g L-1 para Se. Análises de tecido vegetal obtiveram limites de detecção de: 856 mg kg-1 para P; 425 mg kg-1 para K; 289 mg kg-1 para Ca; 10 mg kg-1 para Mn; 16 mg kg-1 para Fe; 3 mg kg-1 para Cu; 5 mg kg-1 para Zn; 2 mg kg-1 para Rb; e 4 mg kg-1 para Sr. Já amostras de solo tiveram limites de detecção de: 914 mg kg-1 para K; 313 mg kg-1 para Ca; 254 mg kg-1 para Ti; 114 mg kg-1 para Mn; 69 mg kg-1 para Fe; 15 mg kg-1 para Rb; 19 mg kg-1 para Sr; e 132 mg kg-1 para Th. As faixas lineares de trabalho das curvas de calibração eram, constantemente, da ordem de 4 à 5 ordens de grandeza, salvo alguns casos onde as curvas foram feitas com amostras de referência certificada que não abrangiam tamanha faixa linear. Por fim, foram feitas análises comparativas entre seiva de soja e solução nutritiva, entre seiva de soja e tecido vegetal e entre tecido vegetal e análises de referência
Título en inglés
Alignment, programming and commissioning of a total reflection X-ray fluorescence (TXRF) vacuum system for application in agricultural and environmental research
Palabras clave en inglés
Elemental analysis
Instrumentation (Physics)
Samples
Total reflection X-ray Fluorescence
X-ray fluorescence
Resumen en inglés
The elementary evaluation of the constituents of a sample is of major importance in agricultural and environmental sciences. These analyses can be performed by various methods and equipments. In this context, the total reflection X-ray fluorescence technique (TXRF) is becoming more consolidated due to detection limits in the order of g L-1 or g kg-1, a wide range of linear response, applicability to elements with Z>11, a non-destructive form of analysis, a small amount of samples and low operational cost. This research project proposed the assembly and commissioning of a TXRF system with high power X-ray tube and automatic sample changer. As a result, the execution of this project provides the scientific community with an alternative tool to conventional analytical techniques. This text explains in detail the equipment assembly processes, the adjustments of the moving parts - such as the monochromator and the reflective substrate - and the experiments developed. As validation of the equipment, calibration curves were built for liquid samples, plant tissues and soils. Liquid analyses had detection limits of: 22.3 g L-1 for Fe; 14.7 g L-1 for Ga; and 14.3 g L-1 for Se. Vegetable tissue analyses had detection limits of 856 mg kg-1 for P; 425 mg kg-1 for K; 289 mg kg-1 for Ca; 10 mg kg-1 for Mn; 16 mg kg-1 for Fe; 3 mg kg-1 for Cu; 5 mg kg-1 for Zn; 2 mg kg-1 for Rb; and 4 mg kg-1 for Sr. Soil samples had detection limits of 914 mg kg-1 for K; 313 mg kg-1 for Ca; 254 mg kg-1 for Ti; 114 mg kg-1 for Mn; 69 mg kg-1 for Fe; 15 mg kg-1 for Rb; 19 mg kg-1 for Sr; and 132 mg kg-1 for Th. The linear work ranges for the calibration curves were constantly of the order of 4 to 5 orders of magnitude, except in some cases where the curves were made with certified reference samples that did not cover such a linear range. Finally, comparative analyses were made between soybean sap and nutrient solution, between soybean sap and plant tissue and between plant tissue and reference analyses
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-11-29
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.