Ana Carolina Soares Succar
Institute/School/College
Knowledge Area
Date of Defense
Published
Bauru, 2023
Supervisor
Committee
Lourençone, Luiz Fernando Manzoni (President)
Felix, Felippe
Hamerschmidt, Rogerio
Massuda, Eduardo Tanaka
Title in Portuguese
Complicações e resultados audiológicos de próteses auditivas percutâneas ancoradas ao osso
Keywords in Portuguese
Aparelhos auditivos
Audiologia
Complicações pós-operatórias
Osteointegração
Prótese osteoancorada
Abstract in Portuguese
Objetivo: Descrever as complicações pós-operatórias e resultados audiológicos dos pacientessubmetidos à cirurgia para colocação de próteses auditivas ancoradas ao osso (PAAO) percutâneas. Método: Análise retrospectiva dos prontuários de 44 pacientes com deficiência auditiva condutiva ou mista bilateral, que realizaram cirurgia para colocação da PAAO sistema Baha Connect® ou Ponto® unilateral, com análise pelo Modelo Linear Generalizado (GLM) para medidas repetidas. Resultados: Foram utilizados 20 Baha® Connect e 24 Ponto® e identificadas complicações em 27 pacientes. Ao compararmos usuários do sistema Ponto® e Baha® Connect, não houve diferença estatística entre as marcas no que se refere à frequência das complicações (p=0,90). Os limiares auditivos obtidos em campo livre melhoraram quando comparamos os dados pré e pós operatórios (p<0,001). No que se refere à percepção da fala, as análises mostraram melhora estatisticamente significante (p<0,001). Conclusão: Foi destacada a alta frequência de complicações associadas às PAAO percutâneas. Entretanto, demonstrou benefício audiológico em todos os testes estudados.
Title in English
Complications and audiological results of percutaneous bone-anchored hearing devices
Keywords in English
Audiology
Bone-anchored prosthesis
Hearing aids
Osseointegration
Postoperative complications
Abstract in English
Background: To describe the postoperative complications and audiological results related to percutaneous bone-anchored hearing devices (BAHDs). Methods: A retrospective review of 44 patients with bilateral conductive or mixed hearing loss who were implanted with unilateral Baha Connect® or Ponto®. Generalized Linear Model (GLM) for repeated measurements was used. Results: Twenty patients were Baha® Connect users, and twenty-four were implanted with Ponto®. Twenty-seven patients had experienced complications. When we compared the frequency of complications between Ponto® and Baha® Connect users, there was no statistical significance (p=0.90). Free-field hearing thresholds were statistically significantly improved when we compared preoperative and postoperative results (p<0,001). The average speech perception also improved (p<0,001). Conclusion: In spite of percutaneous BAHDs having a high rate of complications, they provide significant audiological benefits.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2023-09-18
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.