• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.61.2006.tde-25102006-155947
Documento
Autor
Nombre completo
Marileda Cattelan Tomé
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Bauru, 2006
Director
Tribunal
Trindade Junior, Alceu Sergio (Presidente)
Felicio, Claudia Maria de
Felix, Giedre Berretin
Genaro, Katia Flores
Zorzetto, Neivo Luiz
Título en portugués
Correlação entre achados de palpação e eletromiográficos do músculo orbicular superior da boca em indivíduos com fissura transforame incisivo unilateral reparada
Palabras clave en portugués
eletromiografia
fissura palatina
tônus muscular
Resumen en portugués
Objetivo: Verificar se existe concordância entre examinadores ao avaliar o músculo orbicular superior da boca por meio de palpação, em indivíduos com e sem fissura labiopalatina e verificar se existe correlação dos níveis de atividade eletromiográfica obtidos durante a protrusão labial e durante a emissão da sílaba /pa/, com o grau de tonicidade muscular atribuído pelos examinadores. Modelo: Análise prospectiva comparando um grupo de indivíduos com fissura labiopalatina reparada (GF) e indivíduos sem fissura labiopalatina (GC), a um nível de significância de 5%. Local de Execução: Laboratório de Fisiologia, HRAC-USP. Participantes: 34 indivíduos com fissura labiopalatina transforame unilateral reparada, e 35 indivíduos não fissurados, todos com idade entre 18 a 30 anos. Resultados: os níveis de concordância entre os examinadores ao avaliarem por meio de palpação o músculo orbicular superior são próximos de zero, tanto no GF (E1xE2=0,19; E1xE3= -0,04; E2xE3=0,09) quanto no GC (E1xE2=-0,18; E1xE3=-0,05; E2xE3=-0,07). A correlação entre níveis de atividade eletromiográfica e palpação muscular pelos examinadores por meio de palpação do músculo orbicular superior obtidos durante a protrusão labial (R=-0,002; p=0,983) e durante a emissão da sílaba /pa/ (R=0,120; p=0,325), é negativa. Conclusões: Não houve concordância entre os examinadores ao avaliarem, por meio de palpação, o músculo orbicular superior, tanto para os indivíduos do grupo controle (GC) quanto para os indivíduos do grupo experimental (GF); Houve correlação negativa dos níveis de atividade eletromiográfica obtidos durante a protrusão labial e durante a emissão da sílaba /pa/, com o grau de tonicidade muscular atribuído pelos examinadores.
Título en inglés
Correlation between the findings of palpation and electromyographics from the superior orbicularis oris in individuals with unilateral cleft lip and surgically repaired palate.
Palabras clave en inglés
cleft left palate
electromyography
muscular tonicity
Resumen en inglés
Objective: To verify if there is concordance between examinators when analyzing the superior orbicularis oris through palpation in individuals with and without cleft lip and palate, and verify if there is correlation of the electromyographic activity levels obtained during lips under protrusion and during /pa/ syllable emission, with muscle degree tonicity ascribed by the examinators. Model: A prospective analysis comparing a group of individuals with cleft lip and surgically repaired palate (FG) and individuals without cleft lip and palate (CG), at a significance level of 5%. Setting: Laboratory of Physiology, HRAC-USP. Participants: 34 individuals with unilateral cleft lip and surgically repaired palate and 35 normal individuals, between the ages of 18 and 30 years old. Results: The concordance levels between examinators when analyzing superior orbicularis oris through palpation are close to zero, for GF (E1xE2=0,19; E1xE3=-0,04; E2xE3=0,09) and for GC (E1xE2=-0,18; E1xE3=-0,05; E2xE3=-0,07). The correlation between electromyographic activity level and muscular palpation of the superior orbicularis oris by the examinators, obtained during lips under protrusion (R=-0,002; p=0,983) and during /pa/ syllable emission (R=0,120; p=0,325), is negative. Conclusion: There was no concordance between the examinators when analyzing, through palpation, the superior orbicular oris for both individuals from control group (GC) and from the experimental group (GF). There was negative correlation of the electromyographic activity levels obtained during lips under protrusion and during /pa/ syllable emission, with muscle degree tonicity ascribed by the examinators.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
teseLeda.pdf (554.80 Kbytes)
Fecha de Publicación
2006-10-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.