• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.60.2010.tde-01122010-135234
Documento
Autor
Nombre completo
Tatiana Okura Ajimura
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2010
Director
Tribunal
Gaitani, Cristiane Masetto de (Presidente)
Carrilho, Emanuel
Oliveira, Anderson Rodrigo Moraes de
Título en portugués
Análise do mesilato de imatinibe em plasma empregando a eletroforese capilar
Palabras clave en portugués
eletroforese capilar
extração líquido-líquido
mesilato de imatinibe
plasma
validação
Resumen en portugués
O mesilato de imatinibe é um importante fármaco pertencente à classe dos inibidores da tirosina-quinase, desenvolvido e utilizado atualmente no tratamento da Leucemia Mielóide Crônica. No histórico da utilização deste medicamento, casos de resistência tem sido relatados cujos mecanismos envolvidos, além dos mecanismos celulares, podem estar relacionados ao metabolismo aumentado deste fármaco. O imatinibe é metabolizado principalmente pelo CYP 3A4, cuja atividade enzimática apresenta grande variabilidade interindividual e é suscetível a indução ou inibição por inúmeras co-medicações, constituintes ambientais e dietéticos. Sendo assim uma dose do medicamento pode resultar em concentrações plasmáticas muito diferentes entre pacientes. A maior parte dos métodos existentes para a determinação do imatinibe em amostras biológicas utiliza a cromatografia líquida de alta eficiência. Entretanto, o método desenvolvido e validado neste trabalho propôs a utilização da eletroforese capilar para a análise deste fármaco em plasma. Para isto foi utilizado um capilar de sílica fundida (46,5 cm de comprimento total, 38 cm de comprimento efetivo e 50 µm de diâmetro interno), tampão fosfato de sódio 50 mmol/L, pH 2,5 como eletrólito de corrida, injeção hidrodinâmica por 20 s a pressão de 50 mbar, tensão de 30 kV, temperatura de 35 °C e detecção em 200 nm. O procedimento de preparo das amostras foi baseado na extração líquido-líquido com o éter metil-terc-butílico como solvente extrator. Os parâmetros de desempenho analítico, linearidade, precisão, exatidão, recuperação, limite de quantificação, seletividade e estabilidade, avaliados na validação do método, cumpriram os requisitos preconizados na legislação vigente e o método desenvolvido foi validado com sucesso. Além disso, sua aplicação foi demonstrada na análise de amostras de plasma de pacientes portadores de Leucemia Mielóide Crônica.
Título en inglés
Determination of imatinib mesylate in plasma by capillary electrophoresis
Palabras clave en inglés
capillary electrophoresis
imatinib mesylate
liquid-liquid extraction
plasma
validation
Resumen en inglés
Imatinib mesylate is an important tyrosine kinase inhibitor that has been used for the treatment of Chronic Myeloid Leukemia (CML). Despite the efficacy of imatinib therap, some cases of treatment resistance have been described. A number of mechanisms of resistance have been identified, which include innate or acquired mutations in the BCR-ABL gene, imatinib binding to 1- acid glycoprotein and altered imatinib pharmacokinetics. Imatinib is mainly metabolized by CYP 3A4, whose enzymatic activity presents a large inter-individual variability and is susceptible to induction or inhibition by numerous co-medications, environmental and dietary constituents. Therefore a given dose can yield very different circulating concentrations between patients. The major of methods available for the determination of imatinib in biological samples apply high performance liquid chromatography as analytical technique. However, in this work, we developed and validated a method by capillary electrophoresis for the determination of this drug in human plasma. The analysis was performed using a fused silica capillary (50 µm internal diameter x 46.5 cm total length, 38.0 cm effective length), a 50 mmol/L sodium phosphate buffer pH 2,5 as background electrolyte, hydrodynamic injection time of 20s (50 mbar), voltage of 30 kV, capillary temperature of 35°C and detection at 200 nm. Plasma samples pre-treatment involved liquid-liquid extraction with methyl-terc-butyl ether as extractor solvent. The analytical parameters investigated, linearity, precision, accuracy, recovery, limit of quantification, selectivity and stability, presented in accordance with the confidence criteria established in the literature. Furthermore the application of the method was performed in the analysis of plasma samples from CML patients undergoing treatment with imatinib.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Arquivo.pdf (519.27 Kbytes)
Fecha de Publicación
2011-01-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.