• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.60.2010.tde-08092010-204549
Documento
Autor
Nombre completo
Giovanna de Fatima Moreno Aguiar
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2010
Director
Tribunal
Barbosa Junior, Fernando (Presidente)
Gomes Neto, José Anchieta
Lanchote, Vera Lucia
Título en portugués
Determinação de elementos essenciais e tóxicos em sêmen bovino utilizando a espectrometria de massas com plasma acoplado (ICP-MS) com introdução direta da amostra
Palabras clave en portugués
bovinos
cela de reação dinâmica
ICP-MS
minerais
sêmen
Resumen en portugués
Os minerais são de extrema importância no metabolismo geral e no desempenho produtivo e reprodutivo dos bovinos. Atualmente, no Brasil, existem poucos estudos sobre o diagnóstico de deficiências minerais em bovinos, através de análise de macroelementos e elementos traço em fluidos biológicos. A maior parte das informações disponíveis limitam-se ao diagnóstico clínico de deficiências isoladas e à análise de elementos nas pastagens e no solo, que podem sugerir deficiências sub clínicas de alguns minerais, mas apresentam várias limitações e interferências. O objetivo deste trabalho foi desenvolver um método de análise simples, com introdução direta da amostra, utilizando a técnica de q-ICP-MS e DRC-ICP-MS, para determinação de Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn e Pb em sêmen bovino. Para realização das análises, foi utilizada calibração em meio aquoso e as amostras foram diluídas na proporção 1:50 em solução contendo 0,01% v/v Triton® X-100 e 0,5% v/v de ácido nítrico. Também foram avaliadas a calibração por ajuste de matriz e a análise das amostras após digestão por microondas, para confirmação dos resultados obtidos por introdução direta e calibração em meio aquoso. O DRC foi essencial para determinação de níquel. O gás de reação utilizado foi H2 e os parâmetros RPq e vazão do gás foram estudados para otimização do método. Os limites de detecção para determinação de 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn e 208Pb foram: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectivamente, e para determinação de 60Ni por DRC-ICP-MS o LD foi 0,020 µgL-1. O método desenvolvido foi aplicado para determinação de 15 elementos em amostras de sêmen de bovinos de diferentes raças usadas em programas de reprodução e inseminação artificial.
Título en inglés
Determination of essential and toxicant elements in bovine semen using coupled plasma mass spectrometry (ICP-MS) with direct introduction of the sample.
Palabras clave en inglés
bovines
dynamic reaction cell (DRC-ICP-MS)
ICP-MS
minerals
semen
Resumen en inglés
The minerals are of extreme importance in the general metabolism and in the productive and reproductive performance of the bovines. Nowadays, in Brazil, few studies exist on the diagnosis of mineral deficiencies in bovine, through macroelementos analysis and trace elements in biological fluids. Most of the available information is limited to the clinical diagnosis of isolated deficiencies and the analysis of elements in the pastures and in the soil, that can suggest sub clinical deficiencies of some minerals, but present several limitations and interferences. The objective of this work was to develop a method of simple analysis, with direct introduction of the sample, using the technique of q-ICP-MS and DRC-ICP-MS, for determination of Ca, Cu, Fe, Mg, Zn, I, Mo, As, Se, Ni, Co, Ba, Cs, Mn and Pb in bovine semen. Aqueous medium calibration was used in the analysis and the samples were diluted in the proportion 1:50 in solution containing 0,01% v/v Triton® X-100 and 0,5% v/v of nitric acid. They were also evaluated the matrix matching and the analysis of samples after digestion for microwave, for confirmation of the results obtained by direct introduction and calibration in aqueous medium. DRC went essential for nickel determination. The reaction gas used it was H2 and the parameters RPq and gas flow rate were studied for optimization of the method. The detection limits for determination of 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 127I, 98Mo, 75As, 82Se, 59Co, 138Ba, 133Cs, 55Mn and 208Pb were: 0,262; 0,003; 0,168; 0,004; 0,004; 0,026; 0,007; 0,007; 0,033; 0,002; 0,005; 0,002; 0,003; 0,002 µg L-1 respectively, and for determination of 60Ni for DRC-ICP-MS the LOD was 0,020 µgL-1. The developed method was applied for determination of 15 elements in bovine semen samples of different breed used in reproduction programs and artificial insemination.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
AguiarGFM.pdf (1.65 Mbytes)
Fecha de Publicación
2011-06-21
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.