• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Doctoral Thesis
DOI
https://doi.org/10.11606/T.6.2016.tde-19072016-173236
Document
Author
Full name
João Vicente de Assunção
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 1993
Supervisor
Committee
Nogueira, Diogo Pupo (President)
Agudo, Edmundo Garcia
Alem Sobrinho, Pedro
Colacioppo, Sergio
Silva, Carlos Celso do Amaral e
Title in Portuguese
Viabilidade e importância da redução da emissão de clorofluorcarbonos (CFCS) por reciclagem e controle no uso
Keywords in Portuguese
Camada de Ozônio
CFC
Clorofluorcarbonos
Controle da Poluição do Ar
Poluição do Ar
Poluição Global
Abstract in Portuguese
Uma pesquisa de campo foi conduzida para verificar as condições reais de utilização de clorofluorcarbonos em sistemas de refrigeração e de condicionamento de ar. A pesquisa cobriu os setores de refrigeração de supermercados, ar condicionado de edifícios e oficinas de reparação e de manutenção de geladeiras, "Freezers" e condicionadores de ar compactos e automotivos. A região escolhida para a pesquisa está localizada no município de São Paulo, tendo uma superfície de 12,504 Km2. As seguintes conclusões principais resultaram deste estudo: Predomina o consumo do HCFC 22 nos usuários pesquisados; a reciclagem e a recuperação ocorrem em pequena escala na região estudada; os sistemas de condicionamento de ar automotivos são a fonte mais significativa de substâncias agressivas à camada de ozônio, nos usuários pesquisados; vazamentos ocorrem por práticas de serviço não adequadas; a utilização do CFC 11 para limpeza de circuitos reduz o ganho obtido em sistemas que empregam o HCFC 22; a manutenção preventiva mostrou ser eficaz tanto para reduzir o consumo de gás refrigerante, como para reduzir a substituição de peças e componentes; a reciclagem e a recuperação do gás refrigerante tem efeito positivo em relação à camada de ozônio, economiza recursos naturais, reduz o consumo de energia, os riscos ao meio ambiente e à saúde da comunidade em geral. Finalmente, são feitas recomendações para o estabelecimento de um programa efetivo de reciclagem e recuperação de gases refrigerantes.
Title in English
Feasibility and importance of reducing emissions of chlorofluorocarbons (CFCs) for recycling and control in use
Keywords in English
Air Pollution
CFCs
Chlorofluorocarbons
Control of Air Pollution
Global Pollution
Ozone Layer
Abstract in English
A field study was performed for verifying the actual conditions of the use of chlorofluorcarbons in refrigeration and air conditioning systems. The study has covered the sectors of supermarket refrigeration, building air conditioning systems, and refrigerators freezers and compact and automobile air conditioning systems repair shops. The region chosen for this study is located in the city of Sao Paulo and it has an area of 12.504 km2. The following conclusions resulted from the study: There is a predominance of the of HCFC 22 in the systems surveyied; recycling and recuperation are used in small scale in the region of the study; in the users covered by the study, the automobile air conditioning sector is the most important source of emission of ozone depleting substances; leaks occur because of bad service practices; the use of CFC 11 for circuit cleaning decreases the the gain obtained with the use of HCFC 22; the preventive maintenance has proved to be very efficient both for reducing the consum of refrigeration gases and for reducing the consum of parts and components of the refrigeration system; recycling and recuperation of refrigeration gases have positive effects in relation to the ozone layer, it saves natural resources, and reduces the risk to the enviromnent and to the public health. Finally, recommendations are made for the establishment of an effective refrigerant conservation program.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-07-19
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.