Autor
Nome completo
Rogerio Aparecido Machado
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2003
Orientador
Banca examinadora
Assunção, João Vicente de (Presidente)
Colacioppo, Sérgio
Gatti, Luciana Vanni
Guekezian, Marcia
Philippi Júnior, Arlindo
Título em português
Avaliação de compostos orgânicos voláteis em ambientes interiores climatizados
Palavras-chave em português
Avaliação
Compostos Orgânicos Voláteis
Interiores Climatizados
Poluição do Ar de Interiores
Resumo em português
Tomando por base a Portaria 176 da Agência Nacional de Vigilância Sanitária que cita a necessidade do levantamento de dados sobre compostos orgânicos voláteis - COV - existentes em ambientes fechados climatizados de atividades ocupacionais, foram analisados os compostos orgânicos voláteis no ar interior e exterior de escritórios climatizados do centro da cidade de São Paulo com ausência de tabagismo. As análises foram quantitativas para tetracloreto de carbono, clorofórmio, benzeno e tolueno e qualitativas para as demais substâncias. As amostras foram coletadas através de tubos com carvão ativado e as análises realizadas por Cromatografia Gasosa/Espectrometria de Massas. Foram validados os métodos de coleta e análise utilizados, segundo critério do National Institute for Occupational Safety and Health (NIOSH). Os resultados mostraram ausência de clorofórmio e apenas algumas amostras acusaram traços de tetracloreto de carbono, mas em 76,7% das amostras foi encontrado benzeno e em 100% foi encontrado tolueno, sendo estes em concentrações similares às encontradas na literatura estrangeira. Qualitativamente também foram encontradas as mesmas substâncias citadas nos ambientes interiores climatizados de outros países. Como conclusões foi verificada a existência de COV potencialmente nocivos para saúde, no ar interior de ambientes climatizados, mesmo com ausência de tabagismo. A metodologia adaptada para realizar as coletas e análises demonstrou ser urna alternativa viável e confiável em relação às existentes na literatura técnica. Também foi constatado que a maioria dos COV presentes no ar dos escritórios pesquisados tinham por fonte o ar externo e que os condicionadores de ar tipo SPLIT e de janela concentram as substâncias no ar interno, enquanto os condicionadores centrais promovem a diluição destas substâncias.
Título em inglês
Analysis of volatile organic compounds in acclimatized indoor environments
Palavras-chave em inglês
Acclimatized Indoor
Analysis
Indoor Air Pollution
Volatile Organic Compounds
Resumo em inglês
In accordance with Portaria 176 of Agência Nacional de Vigilância Sanitária, that mentions the need of a data collection of volatile organic compounds -VOC- existing in occupational activity closed acclimatized environments, volatile organic compounds were analyzed in the indoor, and outdoor air of São Paulo City downtown acclimatized offices, where there was no tobacco smoking. Analyses were quantitative for carbon tetrachloride, chloroform, benzene, and toluene, and qualitative for the other substances. Samples were taken into tubes with activated carbon and analyses were performed by Gas Chromatography/Mass Spectrometry. The sampling and analyzing methods used were validated in compliance with criteria of the National Institute for Occupational Safety and Health (NIOSH), USA. Results showed chloroform absence, and only some samples indicated carbon tetrachloride traces, but in 76.7% of the samples benzene was found and in 100% of the samples toluene was detected, these substances were in similar concentrations to those found, respectively, in the foreign literature. Qualitatively, the same substances, as mentioned to be in other countries' acclimatized indoor environments, were also found. As a conclusion, the existence of VOC, potentially harmful for the health, was observed in the air of acclimatized environments, even though without tobacco smoking. The methodology adapted to take the samples, and perform the analyses, proved to be a viable, and reliable alternative if compared to those existing in the technical literature. It was also found out that most part of the VOC present in the air of the investigated offices had outside air as a source, and SPL1T, and window-type air conditioners concentrate these substances in the indoor air, while central air conditioners provide dilution of these substances.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.