• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2023.tde-29052023-075321
Documento
Autor
Nombre completo
José Eduardo Batista
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2023
Director
Tribunal
Murta Junior, Luiz Otavio (Presidente)
Guardia, Hélio Crestana
Nicolucci, Patrícia
Título en portugués
Avaliação de cálculos de distribuição de dose de radiação utilizando unidades de processamento gráfico e algoritmo Monte Carlo: rumo a um suporte ao planejamento em radioterapia
Palabras clave en portugués
Depósito de dose
GPU
Método Monte Carlo
PENELOPE
Programação paralela
Transporte de radiação
Tratamento radioterápico
Resumen en portugués
A simulação computacional utilizando o Método Monte Carlo (MMC) aplicado ao transporte de radiação é considerado padrão ouro em radioterapia, apresentando-se como o método mais exato para a cálculo da dose depositada no tecido alvo e nos órgãos adjacentes. No entanto, o seu longo tempo de processamento computacional necessário para atingir valores satisfatórios de incerteza estatística, torna sua aplicação inviável na clínica médica de rotina. A programação paralela, com implementação de algoritmos para execução em unidades de processamento gráfico (GPUs), tem se mostrado uma das alternativas exploradas por pesquisadores para reduzir o tempo computacional e tornar o uso do MMC clinicamente viável. Este trabalho teve por objetivo a adaptação para execução paralela, em unidades de processamento gráfico, do algoritmo Monte Carlo, aplicado ao transporte de radiação, presente no PENELOPE-2014, visando manter a exatidão e diminuir o tempo computacional necessário para obtenção de resultados como depósito de dose nos corpos e mapa de distribuição de dose. O desenvolvimento foi realizado na plataforma CUDA e tomou como base o pacote PENELOPE-2014, que possui estrutura de execução sequencial em unidades centrais de processamento (CPUs). A comparação dos resultados obtidos das simulações executadas no novo algoritmo paralelo, em GPU, com as simulações executadas no PELENOPE-2014, em CPU, demonstraram um grau de exatidão com diferenças menores do que 1% para depósito de dose e diferenças imperceptíveis para os mapas de distribuições de doses a um fator de desempenho de cerca de 13 vezes mais rápido. A combinação dos ganhos de desempenho com a manutenção da exatidão da simulação, demonstra que a execução paralela na GPU apresenta um potencial de tornar o uso do MMC uma técnica viável para sistemas de planejamento radioterápico.
Título en inglés
Evaluation of radiation dose distribution estimations using graphic processing units and Monte Carlo algorithm: toward a support in radiotherapy planning
Palabras clave en inglés
Dose delive
GPU
Monte Carlo method
Parallel programming
PENELOPE
Radiation transport
Radiotherapy treatment
Resumen en inglés
Computer simulation using the Monte Carlo Method (MCM) applied to radiation transport is considered the gold standard in radiotherapy, presenting itself as the most accurate method for calculating the dose deposited in the target tissue and adjacent organs. However, its long computational processing time, necessary to reach satisfactory statistical uncertainty values, makes its application unfeasible in routine medical practice. Parallel programming, with the implementation of algorithms for execution in graphic processing units (GPUs), is one of the alternatives explored by researchers to reduce computational time and make the use of MMC clinically viable. This work's objective was to adapt the Monte Carlo algorithm for parallel execution, in graphic processing units, applied to radiation transport, present in PENELOPE-2014, aiming to maintain accuracy and reduce the computational time necessary to obtain results such as dose deposit in bodies and dose distribution map. The development was carried out on the CUDA platform and was based on the PENELOPE-2014 package, which has a sequential execution structure in central processing units (CPUs). The comparison of the results obtained from the simulations executed in the new parallel algorithm, in GPU, with the simulations executed in PELENOPE-2014, in CPU, demonstrated a degree of accuracy with differences lower than 1% for dose deposit and imperceptible differences for the maps from dose distributions to a performance factor of about 13 times faster. The combination of performance gains keeping the simulation accuracy demonstrates that parallel execution on the GPU can make MCM a viable technique for radiotherapy planning systems.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2023-05-29
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.