• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.59.2017.tde-17082016-084621
Documento
Autor
Nombre completo
Flávio Venâncio Nakadi
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2015
Director
Tribunal
Veiga, Márcia Andreia Mesquita Silva da (Presidente)
Demets, Gregoire Jean Francois
Ezcaray, Martín Resano
Gomes Neto, José Anchieta
Welz, Bernhard
Título en portugués
Desenvolvimento de procedimentos analíticos para a determinação de não-metais via moléculas diatômicas por espectrometria de absorção molecular de alta resolução com fonte contínua
Palabras clave en portugués
bromo
cloro
deslocamento isotópico
enxofre
HR CS MAS
Resumen en portugués
A espectrometria de absorção atômica (AAS) é consolidada como uma técnica robusta, cujas aplicações estendem-se a diversos analitos e matrizes. Sua limitação encontra-se na região do UV distante (~ 190 nm), por isso ela permaneceu exclusiva à determinação de metais durante vários anos: não-metais geralmente absorvem na região de UV de vácuo. Com o advento da AAS de alta resolução com fonte contínua, houve a implementação de uma terceira dimensão (comprimento de onda) nas análises: a visualização da região espectral da linha analítica. Esta nova característica permitiu um maior número de informações espectrais, principalmente em relação às bandas estruturadas de moléculas diatômicas, o que resultou na determinação de absorção molecular (HR CS MAS). Destarte, o objetivo deste trabalho foi a elaboração de novos procedimentos analíticos para determinação de não-metais por HR CS MAS, especificadamente Br, Cl e S, com atomizador de forno de grafite. O bromo foi avaliado via CaBr em componentes plásticos de amostras eletrônicas, extraído por extração Soxhlet com tolueno, e obteve limites de detecção (LD) e quantificação (LQ) de 4,3 e 14 ng de Br, respectivamente, com Pd como modificador químico. Duas matrizes foram estudadas para a quantificação de enxofre via CS: carvão e diesel. O carvão foi injetado em HR CS MAS como uma suspensão com Triton X-100 0,04 % m v-1, e (NH4)2SO4 foi empregado como padrão de enxofre. Os LD e LQ obtidos para o método foram 0,01 e 0,05 % m m-1, respectivamente. Para o diesel, dois métodos foram estudados: (i) emulsão alcoólica com etanol 50 % v v-1, a qual apresentou LD de 0,12 g kg-1 e LQ de 0,40 g kg-1, adequados para determinação de altos teores de S em diesel; e (ii) injeção direta de diesel no sistema de HR CS MAS, cujos LD e LQ foram 3 e 9 mg kg-1, respectivamente. Ambos empregaram nanopartículas de Pd como modificador químico, das quais a análise direta de diesel obteve melhores resultados. Finalmente, um novo conceito foi investigado em HR CS MAS: o deslocamento isotópico em moléculas diatômicas. Os estados vibracionais e rotacionais presentes na transição eletrônica observada em HR CS MAS confere esta propriedade. As moléculas de AlCl e CaBr, cujos isótopos de interesse foram 35Cl e 37Cl, e 79Br e 81Br, respectivamente, foram estudadas. Os deslocamentos isotópicos observados foram de 15,6 pm para AlCl e 41,6 pm para CaBr nos comprimentos de onda selecionados, suficientes para implementação de calibração por diluição isotópica, a qual apresentou LDs de 2,5 e 64 ng, respectivamente. Amostras de água natural e mineral foram empregadas para o Cl, enquanto o Br foi determinado em amostras de PVC e folhas de tomate, as quais foram introduzidas diretamente como sólidos. A diluição isotópica corrigiu adequadamente as interferências espectrais acarretadas pelas matrizes de ambos os analitos.
Título en inglés
Development of analytical procedures for the determination of non-metals via diatomic molecules by high-resolution continuum source molecular absorption spectrometry
Palabras clave en inglés
bromine
chlorine
HR CS MAS
isotopic shift
sulfur
Resumen en inglés
Atomic Absorption Spectrometry (AAS) is a robust analytical technique whose applications extend to many different analytes and matrices. Its limitation lies on the far UV region (~ 190 nm) and therefore it remained exclusive for metal determination as non-metals typically absorb within the vacuum-UV region. With the invention of the High-Resolution Continuum Source AAS (HR CS AAS), the AAS analysis has been upgraded and a new dimension (wavelength) was added: the visualization of the analytical lines vicinity. This new feature allowed improved spectral information, mainly related to the structured bands of diatomic molecules, giving rise to the HR CS Molecular Absorption Spectrometry (MAS). The goal of this thesis was the evaluation of new analytical procedures for non-metals determination by HR CS MAS, specifically Br, Cl, and S, using graphite furnace as the atomizer. Bromine in plastic electronic components was evaluated as CaBr after Soxhlet extraction with toluene. This method had limits of detection (LD) and quantification (LQ) of 4.3 and 14 -ng, respectively, using Pd as chemical modifier. Sulfur determination via CS molecule employed two distinct matrices: coal and diesel. Coal samples were prepared as a slurry with Triton X-100 0.04% m v1 for injection in the HR CS MAS and the external calibration employed was (NH4)2SO4as sulfur standard. The method LD and LQ were 0.01% m m1 and 0.05% m m1, respectively. Two methods were studied for diesel samples: (i) alcoholic emulsion with ethanol 50% v v1, with an LD of 0.12 g kg1 and an LQ of 0.40 g kg1, suitable for sulfur high concentration determination in diesel; and (ii) direct diesel injection in the HR CS MAS system, whose LD and LQ were 3 mg kg-1and 9 mg kg-1, respectively. Both methods employed Pd nanoparticles as chemical modifier, with better results for direct diesel analysis. Ultimately, a new concept was investigated in HR CS MAS: the isotopic shift of diatomic molecules. An absorption profile consisted of multiple peaks was due to vibrational and rotational energy couplings within the electronic transition observed by HR CS MAS, which provided the isotopic shift. This effect was detected on AlCl and CaBr molecules, whose target isotopes were, respectively, 35Cl &37Cl and 79Br &81Br. The observed isotopic shifts were 15.6 pm (AlCl) and 41.6 pm (CaBr) at the selected wavelengths, appropriate for isotopic dilution calibration, which featured LDs of 2.5 ng and 64 ng, respectively. Natural and mineral water samples were evaluated for Cl determination; and Br was found in PVC and tomato leaves samples, both introduced as solid samples in HR CS GFMAS. Isotopic dilution adequately corrected the spectral interferences derived from the matrices of both analytes.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Tese_Nakadi_FV.pdf (6.23 Mbytes)
Fecha de Publicación
2017-11-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.