• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2021.tde-30092021-144627
Documento
Autor
Nombre completo
Daniel Rodrigues Balbin
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2021
Director
Tribunal
Poletti, Martin Eduardo (Presidente)
Hönnicke, Marcelo Gonçalves
Kakuno, Edson Massayuki
Mazzaro, Irineu
Título en portugués
Imagens de raios X por contraste de fase usando um feixe polienergético: implementação e estudo de um sistema de aquisição
Palabras clave en portugués
Contraste de atenuação
Contraste de fase
Propagação de raios X na matéria
Raios X
Resumen en portugués
Nas imagens tradicionais de raios X, o receptor de imagem é colocado logo após o paciente. O contraste da imagem resulta de variações na atenuação de raios X decorrentes de diferenças em composição, densidade e espessura dos tecidos, bem como das energias dos raios X utilizados para formar a imagem. Quando o receptor é colocado a uma certa distância do paciente, a imagem responde também às mudanças de fase dos raios X ocorridas conforme a radiação o atravessa. São formadas assim, as imagens de contraste de fase de raios X. Neste trabalho foi estudado, implementado e aplicada a técnica de imagens de contraste de fase de raios X utilizando uma fonte de raios X com microfoco (alta coerência espacial), essencialmente polienergética, e detectores digitais odontológicos, ambos compatíveis com as fontes convencionais e detectores utilizados clinicamente. Inicialmente todos esses elementos foram caracterizados e, em seguida, o arranjo experimental foi montado e a influência dos parâmetros geométrico e de irradiação foram avaliadas nas imagens. Finalmente, diversos objetos simuladores (contendo fibras e materiais homogêneos nas suas propriedades de atenuação) e tecidos animais (ósseo, fibrosos, adiposos e mistos) foram analisados com o arranjo. O protótipo implementado mostrou um grande potencial para aplicações biológicas e clínicas, mostrando um aumento expressivo no contraste de materiais biológicos e inorgânicos com características similares de atenuação, em comparação com as imagens tradicionais de raios X usando o mesmo espectro de energia.
Título en inglés
X-ray phase contrast imaging using a polyenergetic beam: Implementation and study of an acquisition setup
Palabras clave en inglés
Microstructures
Phase contrast
Propagation arrangement
X-Rays
Resumen en inglés
In conventional X-ray imaging contrast the image receptor is placed immediately after the patient. The image contrast results from the variations on the attenuation of X-rays within the patient due to the differences in composition, density and thickness of the tissues, as well as of the X-rays energies emitted from the source. When the receptor is placed in a certain distance from the object, the image also responds to the changes in phase of the X-rays occurred as the radiation penetrate the patient. Thus, X-ray phase contrast images are formed. In this work, the X-ray phase contrast imaging technique was studied, implemented and applied using a microfocus X-ray source (high spatial coher-ence), essentially polyenergetic, and digital dental detectors, both compatible with conventional sources and detectors used clinically. Initially, all these elements were characterized and then the experimental setup was built and the influences on the images of geometric and irradiation parameters were evaluated. Finally, several phantoms (containing fibers and homogeneous materials) and animal tissues (bone, fibrous, adipose and mixed) were analyzed with this prototype system. The implemented prototype system showed great potential for biological and clinical applications, showing a significant increase in the contrast of biological and inorganic materials with similar attenuation characteristics, compared to the traditional X-ray images using the same energy spectrum.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2021-10-01
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.