Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2020.tde-28022020-103544
Documento
Autor
Nombre completo
Danny Giancarlo Apaza Veliz
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2019
Director
Tribunal
Moraes, Eder Rezende (Presidente)
Brunetto, Sergio Querino
Nicolucci, Patrícia
Rocha, Euclides Timoteo da
Título en portugués
Dosimetria em terapia radioablativa com iodo 131
Palabras clave en portugués
Dosimetria interna
Medicina nuclear
Terapia ablativa
Resumen en portugués
Foi realizada a dosimetria externa de pacientes, após ressecção total da tireóide, submetidos à terapia ablativa com Iodo 131 (131I), o estudo envolveu 43 pacientes (11 homens e 32 mulheres; faixa etária: de 26 a 60 anos) no Departamento de Medicina Nuclear do Hospital de Câncer de Barretos. Foi feita uma comparação da metodologia observada na bibliografia de medida da taxa de dose a 1 metro e a metodologia da CNEN que indica a mesma medida a 2 metros. Os parâmetros biocinéticos dos pacientes foram determinados usando-se o ajuste biexponencial da evolução temporal da taxa de dose equivalente externa proposto, obtiveram-se valores da constante de eliminação do resto do corpo (λc) de 1,47±0,37 d-1 e 1,40±0,38 d-1 a 1 e 2 metros, respectivamente. Para os valores da constante de eliminação da tireoide (λt) obtiveram-se valores de 0,27±0,19 d-1 e 0,26±0,13 d-1 a 1 e 2 metros, respectivamente. Também foram obtidos os valores da constante de taxa de dose no ar (h), 40,53±9,76 e 50,94±15,46 µSv.GBq.h-1 a 1 e 2 metros, respectivamente. Na segunda parte do trabalho realizou-se o desenvolvimento de um protocolo simples para quantificação da atividade através de imagens planas com 131I feitas em objetos simuladores da tireóide para obtenção do coeficiente de calibração da gama câmara (Ccg), obtendo-se um valor de Ccg de 0,07±0,01 MBq.cps-1. Também foi desenvolvida uma metodologia para determinar o volume e a massa ou remanescente da tireóide. Para isto foram utilizadas 7 diferentes configurações dos objetos simuladores para adquirir imagens que permitam quantificar os volumes e massas usando nas imagens obtidas com as diversas montagens dos objetos simuladores como, tireoide de lóbulos simétricos, tireoide de lóbulos assimétricos e o cilindro do fantoma comercial Jacszack, no análise das imagens foram usados os softwares ImageJ (livre descarga) e Xeleris 4.0 (software da gama câmara). O resultado de todas estas avaliações e quantificações mostra que podem ser utilizados e ainda melhorados com fins de dosimetria em terapia ablativa com 131I.
Título en inglés
Dosimetry in radioablative therapy with iodine 131
Palabras clave en inglés
Ablative therapy
Internal dosimetry
Nuclear medicine
Resumen en inglés
It was performed on external dosimetry of patients, after total thyroid resection, immersion in ablative therapy with Iodine 131 (131I) or study involving 43 patients (11 men and 32 women; age range: 26 to 60 years) at the Department of Medicine Nuclear of the Barretos Cancer Hospital. A compilation of the methodology observed in the bibliography of dose rate measurements at 1 meter was made and the CNEN methodology that indicates the same measurement at 2 meters. The biokinetic parameters are two patients determined through a bi-exponential adjustment of the temporal evolution of the proposed external equivalent dose rate, values obtained from the corporate elimination constant (λc) of 1.47±0.37 d-1 and 1.40±0.38 d-1 at 1 and 2 meters, respectively. For the tire removal constant values (λt), values of 0.27±0.19 d-1 and 0.26±0.13 d-1 were obtained at 1 and 2 meters, respectively. Values of constant rate in the air dose (h), 40.53±9.76 and 50.94±15.46 µSv.GBq.h-1 at 1 and 2 meters, respectively, were also obtained. In the second part of the work carried out or in the development of a simple protocol for quantifying the activity, using flat images with the simulating objects of the thyroid objects through the calibration coefficient of the range of cameras (Ccg), obtaining a value of 0.07 ± 0.01 MBq.cps-1 for Ccg. I also developed a methodology to determine the volume and volume of the thyroid. For this purpose, 7 different configurations are used for two simulator objects to obtain images that allow quantifying volumes and masses using two images obtained with different assemblies, two simulator objects such as symmetrical lobe thyroid, asymmetric lobe eyelid or commercial ghost cylinder Jacszack, no Analysis of imagers used for the ImageJ software (free download) and Xeleris 4.0 (camera line software). Or as a result of all these assessments and quantifications, we have shown that they can be used in addition to the dosimetry purposes in 131I ablative therapy.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-05-15
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.