• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2020.tde-24092020-082923
Documento
Autor
Nombre completo
Breno Filipe de Andrade
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2020
Director
Tribunal
Moraes, Eder Rezende (Presidente)
Bonifacio, Daniel Alexandre Baptista
Nicolucci, Patrícia
Pozzo, Lorena
Título en portugués
Avaliação de desempenho de um PET elíptico para corpo inteiro por simulação Monte Carlo usando o programa GATE
Palabras clave en portugués
Medicina nuclear
Simulação Monte Carlo
Tomografia por emissão
Resumen en portugués
Este trabalho tem como objetivo avaliar a viabilidade de um tomógrafo por emissão de pósitrons (PET) de seção transversal com formato elíptico de corpo inteiro com comprimento de 2,0 m para posterior comparação com o sistema EXPLORER, um PET de corpo inteiro. A geometria elíptica permitiu a redução do número de detectores em 16,67% em comparação com o sistema cilíndrico, o que para um tomógrafo de 2,0 m é ainda mais expressivo. A avaliação foi realizada por meio de simulação de Monte Carlo usando o programa GATE 8.1 e os testes foram idealizados com base no já estabelecido protocolo NEMA para tomógrafos de emissão de pósitrons, o NE MANU 2-2007. Foram realizados dois testes, o de resolução espacial e de medida de desempenho de contagens. Em geral, a resolução espacial do sistema cilíndrico foi melhor que o sistema elíptico para os pontos em que foram obtidos. É notável que as posições centrais, tanto para o sistema cilíndrico como elíptico se comportam melhor que as posições periféricas, onde há maior degradação da imagem, como esperado. A medida de desempenho de contagens revelou que o sistema elíptico é mais sensível ao efeito do tempo morto.
Título en inglés
Performance evaluation of elliptical total-body PET using the software GATE
Palabras clave en inglés
Monte Carlo simulation
Nuclear medicine
PET
Resumen en inglés
This work aims to evaluate the viability of a total-body positron emission tomography (PET) with 2.0 m long whose the cross-section has an elliptical shape for later comparison with the EXPLORER system. The elliptical geometry allowed the number of detectors to be reduced by 16.67% compared to the cylindrical system, which for a 2.0 m scanner is quite expressive. The performance was measured by Monte Carlo simulation using the GATE v8.1 and the tests were designed based on the already established NEMA protocol for positron emission tomographs, the NEMA NU 2-2007. Two tests were carried out, spatial resolution and measurement of counting performance. In general, the spatial resolution of the cylindrical system was better than the elliptical system for the points at which they were obtained. It is notable that the central positions, both for the cylindrical and elliptical systems, perform better than the peripheral positions, where there is greater image degradation, as expected. The elliptical system has a higher sensitivy to count rate test and hence to dead time effect, as shown by performance measurement of counts rate.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2020-11-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.