• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.59.2013.tde-19112013-115103
Documento
Autor
Nome completo
Guilherme de Oliveira Silva
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2013
Orientador
Banca examinadora
Mulato, Marcelo (Presidente)
Bianchi, Rodrigo Fernando
Riul Júnior, Antonio
Título em português
Biossensor de ureia utilizando dispositivo pH-EGFET
Palavras-chave em português
biossensor de ureia
EGFET
EnFET
FTO
sensor de íons.
Resumo em português
Sensores são dispositivos capazes de captar um determinado sinal físico -químico do meio e converte-lo num sinal elétrico mensurável por meio de um transdutor. Biossensor é um sensor que tem como parte funcional um receptor biológico específico a determinado analito alvo. Os sinais físico-químicos experimentados por estes dispositivos são convertidos em sinais elétricos de magnitude proporcional à concentração de um ou mais compostos químicos. Neste trabalho, foi construído um sensor de pH utilizando filmes finos comerciais de óxido de estanho dopado com flúor (FTO) como receptor a íons. O sensor foi feito ligando-se amostras de FTO ao terminal de porta de um transistor de efeito de campo do tipo MOS (Metal Oxide Semiconductor). Quando colocado em solução, os íons presentes interagem com a amostra sendo adsorvidos na superfície do filme de FTO. O potencial gerado pelos íons adsorvidos modulam a tensão na porta do transistor e, desta maneira, pode -se determinar a concentração dos íons presentes na solução de acordo com a magnitude da resposta do transistor. A este tipo de dispositivo dá -se o nome de EGFET (Extended Gate Field Effect Transistor). O EGFET construído apresentou responsividade de 55 mV/pH e resposta linear em soluções de pH 2 ao 12. Através de técnicas de imobilização enzimática foi possível ligar covalentemente proteínas urease sobre a superfície dos filmes de FTO, convertendo o sensor de pH em biossensor de ureia. Soluções tampão com diferentes pHs e concentrações foram testadas e determinou -se que as condições ideais para o uso deste biossensor de ureia são soluções tampão com pH = 6 e concentração de 10mM. Nessas condições, o biossensor apresentou uma responsividade de 114,5 mV/p(ureia) e linearidade no intervalo de concentrações de ureia entre 3,2.10 -4 e 3,2.10 -2 mol/L.
Título em inglês
Urea biosensor based on pH-EGFET technology.
Palavras-chave em inglês
EGFET
EnFET
FTO
ion sensor.
urea biosensor
Resumo em inglês
Sensors are devices capable of capturing a certain physical-chemical signal from environment and convert it into a measurable electrical signal by a transducer. Biosensor is a sensor which has a biological sensing element as receptor specific to a particular target analyte. The physical-chemical signals experienced by these devices are converted into electrical signals with magnitude proportional to the concentration of one or more chemical compounds. In this work, we built a pH-sensor using commercial thin films of tin oxide doped with fluorine (FTO) as ions receptor. The sensor was made by linking FTO samples to the gate of a field effect transistor MOS type. In solution, the ions interact with the sample being adsorbed on the surface of FTO film. The potential generated by the ions adsorbed on film's surface modulate the gate voltage of the transistor and, in this way, we can determine the concentration of ions present in solution correlated with the magnitude of the transistor response. This kind of device is given the name of EGFET (Extended Gate Field Effect Transistor). The EGFET built exhibits sensitivity of 55 mV/pH and linear response in the range of pH 2 to 12. Through enzyme immobilization techniques we could covalently bind urease proteins on the surface of FTO film, changing the pH-sensor in urea biosensor. Buffer solutions with differents pHs and concentrations were tested and was determined that optimal environment conditions for this urea biosensor is buffer solutions with pH = 6 and 10mM of concentration. Under these conditions, the biosensor showed sensitivity of 114.5 mV/p(urea) and linear response in the range of 3,2.10 -4 to 3,2.10 -2 mol/L
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2014-04-02
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.