Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2008.tde-16072008-114028
Document
Author
Full name
Alexandre Parizoti
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2008
Supervisor
Committee
Ghilardi Netto, Thomaz (President)
Costa, Alessandro Martins da
Furquim, Tânia Aparecida Correia
Title in Portuguese
Otimização de imagens e proteção radiológica em fluoroscopia
Keywords in Portuguese
fluoroscopia
intervencionista
Otimização
otimização.
Abstract in Portuguese
Este trabalho teve como objetivo avaliar a proteção radiológica em procedimentos fluoroscópicos intervencionistas através de testes de controle de qualidade e levantamento radiométrico, bem como a implementação de um objeto simulador para avaliação da qualidade da imagem e sua otimização, com conseqüente redução da dose no paciente. O objeto simulador, desenvolvido para avaliação de equipamentos de radiologia convencional, mostrou-se eficaz na avaliação da qualidade da imagem em fluoroscopia, bem como na determinação dos níveis de taxa de kerma no ar na entrada da pele de um paciente adulto normal. A avaliação dos parâmetros técnicos dos diversos modos de exposição de um equipamento fluoroscópico digital permitiu estabelecer os indicadores de dose para otimização das imagens em procedimentos intervencionistas. Esta otimização possibilita reduzir a dose no paciente mantendo a qualidade da imagem e, conseqüentemente, sem perda de informação diagnóstica.
Title in English
Optimizing Images and Radiological Protection in Fluoroscopy
Keywords in English
Fluoroscopy
Optimization and intervencionist.
Abstract in English
This work had as main objective to evaluate the radiological protection in the interventional procedures radiology through quality control and evaluations radiometric, as well as the implementation of a phantom for evaluation of the image quality and the consequent reduction of dose in the patient. The developed simulator object for equipment evaluation of conventional radiology had been revealed efficient in the evaluation of the quality of the fluoroscopic image, as well as in the determination of the entrance surface air kerma rate of the normal adult patient skin. The evaluation of the parameters technician in the diverse ways of exposition of digital fluoroscopy equipment allowed establishing the pointers of improve dose for improve the quality of the images in interventionist procedures. This makes possible to reduce the dose in the patient keeping the quality of the image and, without loss of diagnostic information.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Mestrado.pdf (1.50 Mbytes)
Publishing Date
2009-03-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.