Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2010.tde-13072010-105537
Documento
Autor
Nombre completo
Roberta Giglioti
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2010
Director
Tribunal
Ghilardi Netto, Thomaz (Presidente)
Hornos, Yvone Maria Mascarenhas
Nicolucci, Patrícia
Título en portugués
Utilização da dosimetria opticamente estimulada (OSL) na avaliação de parâmetros de qualidade de feixe em radioterapia
Palabras clave en portugués
Controle de qualidade em radioterapia
Dosimetria OSL
Radioterapia
Resumen en portugués
O controle de qualidade do feixe é fundamental para garantir os requisitos mínimos de operação aos serviços de radioterapia, visto que a avaliação de parâmetros como simetria, planura, penumbra, fatores filtro e bandeja além de outros parâmetros dosimétricos é imprescindível para garantir constância aos tratamentos radioterápicos minimizando erros na entrega da dose. A avaliação destes parâmetros em radioterapia normalmente é realizada através de câmaras de ionização, filmes radiográficos ou detectores semicondutores sendo eles diodos e MOSFETs. Nos últimos anos o crescimento da utilização da dosimetria opticamente estimulada (OSL) na dosimetria individual externa em diversos países da Europa, USA e America latina como México e Peru proporcionou a aplicação de detectores OSL também na dosimetria em radioterapia visando à avaliação de parâmetros de feixe. A técnica de OSL une características técnicas encontradas em filmes e TLD, acrescidas de novas propriedades não possíveis nas tecnologias utilizadas anteriormente, por exemplo: possibilidade de re-leitura do dosímetro, integração de dose com avaliação de doses intermediárias entre exposições no mesmo dosímetro e simplicidade no processo de leitura. Recentemente a Landauer Inc lançou no mercado americano fitas dosimétricas de OSL para a análise do perfil de dose em Tomografia Computadorizada (TC). Neste trabalho foi avaliada a utilização deste detector OSL em forma de fita, na determinação de parâmetros de qualidade em radioterapia tais como simetria e planura, fatores filtro e bandeja, porcentagem e dose profunda (PDP) e penumbra. Os resultados obtidos permitem concluir que o detector estudado se apresenta eficaz na determinação dos parâmetros de qualidade, porém a metodologia de análise de dados bem como o setup utilizado na irradiação inicial devem ser reformulados buscando obter resultados mais precisos de forma a validar a utilização deste método na rotina de trabalho em radioterapia.
Título en inglés
Utilization of optically stimulated dosimetry (OSL) to evaluate beam parameters of quality in radiotherapy
Palabras clave en inglés
OSL dosimetry
Quality control in radiotherapy
Radiotherapy
Resumen en inglés
Beam´s quality control is fundamental to ensure minimum operation requirements to radiotherapy services, since parameters evaluation, such as symmetry, planura, shade, filter factors and tray, amongst other ones, is necessary to guarantee stability to radiotherapy treatments, which minimize errors at dose delivery. The evaluation of those parameters in radiotherapy is normally executed through ionization compartments, radiographic films or semiconductor detectors, specifically diode and MOSFETs. Through the last years, the utilization of optically stimulated dosimetry at external individual dosimetry increased in several Europe countries, USA and Latin America countries, such as Mexico and Peru, which made it possible to apply OSL detectors at dosimetry to radiotherapy as well, in order to evaluate clusters parameters of quality. The OSL technique incorporate technical characteristics, found in films and TLD, to new proprieties, which were not available at preceding technologies, such as: possibility of dosimetry rereading, dose integration with intermediary doses evaluation between exposure at the same dosimeter and simplicity at the reading process. Recently, Launder Inc launched in the American market OSL dosimetric ribbons to dose profile analysis in computed tomography (TC). In this paper, it was analyzed this OSL tape shaped detector utilization, in order to determine parameters of quality in radiotherapy, such as symmetry and beam flatness, filter factors and tray, depth dose percentage and dose and shade. The results allowed to conclude that the studied detector is effective to determine parameters of quality. However, analysis methodology, as well as the used setup at initial irradiation, must be reformulated in order to get more accurate results, which it will allow to validate this method utilization at daily work routine in radiotherapy.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2010-07-22
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.