• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.59.2007.tde-12052008-150030
Document
Author
Full name
Lindomar Soares dos Santos
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2007
Supervisor
Committee
Costa, Alessandro Martins da (President)
Caldas, Linda Viola Ehlin
Nicolucci, Patrícia
Title in Portuguese
Implementação de um sistema dosimétrico termoluminescente para utilização em dosimetria in vivo em teleterapia com feixes de fótons de energia alta
Keywords in Portuguese
dosimetria in vivo
dosimetria termoluminescente
sistema dosimétrico termoluminescente
TLD
Abstract in Portuguese
A dosimetria in vivo é a verificação final da dose real administrada ao paciente e tornou-se atualmente necessária devido ao aumento da complexidade e da sofisticaçã das técnicas radioterápicas. A finalidade deste trabalho foi apresentar, verificar e avaliar alguns procedimentos básicos, práticos e viáveis para a implementação da dosimetria in vivo com dosímetros termoluminescentes na verificação de dose em um serviço de radioterapia. Para o estabelecimento do sistema dosimétrico termoluminescente, alguns testes e medições foram realizados, incluindo o procedimento de inicialização, a determinação da homogeneidade do grupo de dosímetros, a determinação do fator de correção individual de cada dosímetro, a determinação da faixa de linearidade do sistema e do coeficiente de calibração. Medições em um objeto simulador antropomórfico foram realizadas para garantir que os métodos utilizados são satisfatórios antes que estes fossem usados para medições em pacientes. Medições de dose em um paciente foram feitas em um tratamento de câncer de próstata. A metodologia proposta pode ser usada como parte de um programa de garantia de qualidade em um serviço de radioterapia.
Title in English
Implementation of a thermoluminescent dosimetric system for use in in vivo dosimetry on radiotherapy with external high energy photon beams
Keywords in English
in vivo dosimetry
thermoluminescent dosimetric system
thermoluminescent dosimetry
TLD
Abstract in English
In vivo dosimetry is the ultimate check of the actual dose delivered to an individual patient and has become a procedure actually necessary due to increasing complexity and sophistication of radiotherapy techniques. The purpose of the present work was to present, verify and evaluate some basic, practical and viable procedures for the implementation of in vivo dosimetry with thermoluminescent dosimeters for patient dose verification at a radiotherapy service. For the setting up of the thermoluminescent dosimetric system, several tests and measurements were carried out including the initialisation procedure, the determination of the batch homogeneity, the determination of individual correction factor of each dosimeter, the determination of linearity range of the system and its calibration coefficients. Anthropomorphic phantom measurements were taken to ensure that the methods are satisfactory before they are used for patients measurements. Patient dose measurements were carried out in a prostate cancer treatment. The proposed methodology can be used as a part of a quality assurance program in a radiotherapy service.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
LindomarSoares.pdf (223.01 Kbytes)
Publishing Date
2008-05-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.