• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.59.2016.tde-09032016-154506
Document
Auteur
Nom complet
Jessica Colnaghi Fernandes
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2016
Directeur
Jury
Mulato, Marcelo (Président)
Condeles, José Fernando
Guerra, Elidia Maria
López, Johnny Vilcarromero
Oliveira, Marcelo Firmino de
Titre en portugais
Biossensores de pH, ureia e glicose utilizando a microeletrônica de filmes finos de AZO e TIO2
Mots-clés en portugais
AZO
biossensores
glicose
pH
TiO2
ureia
Resumé en portugais
Este trabalho apresenta o desenvolvimento de biossensores de pH, ureia e glicose, utilizando óxidos como plataforma para a parte seletiva. Os filmes finos de óxidos condutores foram produzidos por diferentes técnicas de deposição, como spin-coat, dip-coat, spray-pyrolysis e casting. Os materiais fabricados foram AZO e TiO2, ambos depositados sobre substratos de FTO, ITO ou vidro hidroflilizado. O número de camadas foi variado para cada técnica e as caracterizações morfológicas e estruturais foram feitas por MEV, DRX e FTIR. As caracterizações elétricas foram feitas por EGFET e voltametria cíclica. Os filmes foram testados como sensores de pHs na faixa de 2 a 8. O filme depositado com AZO em substrato de FTO pela técnica de spray-pyrolysis apresentou melhor resposta, com sensibilidade de 31,7 mV/pH entre toda a faixa de pHs do 2 ao 8. Já para os filmes de TiO2, o filme produzido por dip-coat com 5 camadas em substrato de FTO apresentou sensibilidade de 37,8 mV/pH entre a faixa de pHs de 2 a 8. Paralelamente, os filmes tiveram suas superfícies funcionalizadas com proteínas como urease ou glicose oxidase. Neste caso, os dispositivos foram testados entre as concentrações de 5 a 200 mg/dL de ureia e glicose. Como biossensor de ureia, o filme de TiO2 depositado por spin-coat com 5 camadas em substrato de FTO apresentou a maior sensibilidade, com valor 3,32 mV/(mg/dL) entre as concentrações de 5 a 120 mg/dL. Para os filmes estudados como biossensores de glicose, o melhor resultado também foi obtido pelo filme de TiO2 depositado por spin-coat com 5 camadas em substrato de FTO, apresentando sensibilidade em torno de 6,18 mV/(mg/dL) entre as concentrações de 5 a 200 mg/dL. Alguns resultados encontrados foram iguais ou melhores aos encontrados na literatura vigente, mesmo que os dispositivos ainda são passíveis de otimização.
Titre en anglais
pH, urea and glucose biosensors by the use of microelectronic of AZO and TiO2 thin films
Mots-clés en anglais
AZO
biosensors
glucose
pH
TiO2
urea
Resumé en anglais
This study presents the development of pH, urea and glucose biosensors, by the use of oxides as the base of the sensing membrane. Conducting oxide thin films were prepared by different deposition techniques, such as spin-coat, dip-coat, spray-pyrolysis, and casting. AZO and TiO2 were produced and coated onto FTO, ITO and glass substrates. The number of layers were changed for each deposition technique, and the surface characterizations were made by SEM, XRD and FTIR, while the electrical characterizations were performed with an EGFET device and cyclic voltammetry. The samples were used as pH sensors in the pH range from 2 to 8. The AZO thin film onto FTO substrate deposited by spray-pyrolysis deposition technique presented sensitivity as 31.7 mV/pH for the total pH range from 2 to 8. TiO2 thin films, produced by dip-coat deposition technique with 5 layers onto FTO substrate presented 37.8 mV/pH as sensitivity, for the same pH range. All the films have their surfaces immobilized with proteins as urease or glucose oxidase. In this case, the samples were performed in different concentrations of urea or glucose, respectively, from 5 to 200 mg/dL, for both. Urea biosensors presented good results for measurements performed with the same sample as well as performed with individuals samples, for all the concentrations range. Spin-coated TiO2 thin films with 5 layers onto FTO substrates presented 3.32 mV/(mg/dL) as sensitivity from 5 to 120 mg/dL urea concentrations, while for glucose biosensors presented 6.18 mV/(mg/dL) for the same film between the glucose concentration range from 5 to 20 mg/dL. Some results were equal or better than the results in current literature, even the films are still capable of optimization.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Corrigida.pdf (9.89 Mbytes)
Date de Publication
2016-05-12
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.