• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.59.2021.tde-06122021-154654
Document
Auteur
Nom complet
Julio Godeli Neto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2021
Directeur
Jury
Poletti, Martin Eduardo (Président)
Cardoso, Simone Coutinho
Cunha, Diego Merigue da
Marques, Paulo Mazzoncini de Azevedo
Titre en portugais
Mamografia digital por dupla energia usando simulação Monte Carlo: otimização da quantificação da morfologia de microcalcificações e componentes do tecido mamário
Mots-clés en portugais
Dupla-energia
Mamografia digital
Otimização
Quantificação
Simulação
Resumé en portugais
A técnica de mamografia por dupla energia, que consiste na combinação de imagens mamográficas convencionais, pode ser utilizada para realçar, suprimir e quantificar características da mama, que indiquem precocemente a formação de carcinomas. O objetivo deste trabalho é o estudo e a otimização de imagens mamográficas geradas por dupla energia, para a verificação e quantificação de microcalcificações e frações de tecido glandular. As simulações computacionais das imagens produzidas por um mamógrafo digital completo, foram realizadas a partir do código PENELOPE (Penetrarion and Energy Loss of Positrons and Electrons) adaptado. O modelo geométrico implementado permite considerar diferentes espectros, modelos de mama e detectores de imagem. As adaptações do código PENELOPE para geração de imagens e cálculos de grandezas dosimétricas foram devidamente validadas. As imagens simuladas passaram por um pré-processamento para correção de espalhamento, o qual foi capaz de reduzir até 95% da contribuição dos feixes espalhados. O ruído propagado pelas imagens combinadas foi estudado e corrigido através da aplicação de um filtro mediana. Esta técnica foi capaz de reduzir até 60% do ruído propagado e a melhor ponderação de doses para a combinação das imagens foi encontrada. Após isso, as imagens mamográficas já processadas, foram devidamente combinadas e otimizadas. Para esta etapa, fantomas de calibração foram simulados. Com enfoque no realce de microcalcificações, foi encontrada uma região ótima de combinações de energias, centralizada em 28 e 44 kVp. Já para a acurácia de quantificação, foi encontrada uma região ótima centralizada em 28 e 75 kVp, com a qual, foi obtida uma exatidão superior à 93%. Já para a fração glandular, praticamente todas as combinações de energias se mostraram ótimas, com uma acurácia superior à 90%.
Titre en anglais
Digital dual-energy mammography using Monte Carlo simulation: optimization of the quantification of microcalcifications morphology and breast tissue components
Mots-clés en anglais
Digital mammography
Dual-energy
Optimization
Quantification
Simulation
Resumé en anglais
The dual-energy mammography imaging technique, which consists of the combination of two conventional mammographic images, can be used to enhance, suppress and quantify breast characteristics that indicate early cancer formation. This work aims to study and optimize the dual-energy images for the verification and quantification of microcalcifications and glandular tissue fractions. Computer simulations of images generated by a digital mammography system were performed using an adapted PENELOPE code (Penetrarion and Energy Loss of Positrons and Electrons). The implemented geometric model allows to consider different spectra, breast models and image detectors. The PENELOPE code adaptations for image generation and calculations of dosimetric quantities were properly validated. The simulated images underwent a pre-processing for scattering correction, which was able to reduce up to 95% of the scattered beam contribution. The noise propagated in the combined images was studied and corrected through the application of a median filter. This technique was able to reduce up to 60% of the propagated noise and an optimum dose weighting for the combination of images was found. After that, the mammographic images, already processed, were properly combined and optimized. For this step, calibration phantoms were simulated. Focusing on the microcalcifications enhancement, an optimal region of energy combinations was found, centered at 28 and 44 kVp. As for the quantification accuracy, an optimal region centered at 28 and 75 kVp was found, in which, was obtained an accuracy higher than 93%. For glandular fraction estimation, practically all energy combinations proved to be excellent, with an accuracy greater than 90%.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2022-01-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.