• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.59.2006.tde-31012007-100612
Documento
Autor
Nombre completo
Waldemar Galante Junior
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2006
Director
Tribunal
Silva, Jose Aparecido Da (Presidente)
Fukusima, Sergio Sheiji
Silva, Ester da
Título en portugués
Percepção do esforço físico: comparação entre as escalas visual analógica e CR10 de Borg
Palabras clave en portugués
escalas psicofísicas
esforço
exercício
percepção
Resumen en portugués
A proposta deste estudo foi determinar se as escalas visual analógica (VAS) e CR10 (Category-Ratio) de Borg são eficientes para avaliar o esforço geral percebido em um teste de exercício físico dinâmico contínuo. A amostra foi composta por 20 participantes do sexo masculino, com idade entre 18 e 29 anos, universitários, saudáveis, sedentários e que apresentavam valores ergoespirométricos compatíveis com a normalidade (Consenso Brasileiro de Ergometria). Os participantes realizaram o protocolo do teste de exercício físico dinâmico contínuo do tipo rampa (TEFDC-R) em um cicloergômetro eletromagnético à 60 rpm, juntamente com a aplicação das escalas psicofísicas escolhidas. A freqüência do esforço na presença do exercício foi induzida através do aumento da complexidade e da resistência, com a utilização do teste já mencionado. Para a análise dos dados foi utilizada análise psicofísica e estatística paramétrica por meio da correlação de Pearson, regressão linear e teste t de Student. Foram encontradas correlações estatisticamente significativas (p<0,05) entre as escalas (r=0,97), as escalas em função do consumo de oxigênio (CR10: r=0,90; VAS: r=0,90) e em função da freqüência cardíaca (CR10: r=0,89; VAS: r=0,91). Foram encontrados também julgamentos precisos independente da escala utilizada (n=0,99; r2=0,998). Estes resultados sugerem que as magnitudes físicas das escalas VAS e CR10 de Borg são altamente correlacionadas. Além disso, em ambas as escalas, o aumento da potência, da freqüência cardíaca e do consumo de oxigênio corresponderam ao aumento das estimativas subjetivas dos participantes em relação ao esforço físico. Isto pode indicar uma boa interação entre as diferentes variáveis atuantes durante o exercício físico dinâmico contínuo.
Título en inglés
Perception of physical exertion: a comparison between the visual analogue and Borg´s CR10 scales
Palabras clave en inglés
exercise
exertion
perception
psychophysical scales
Resumen en inglés
The purpose of this study was to determine if the visual analogue and Borg´s CR10 (Category-Ratio) scales are efficient for assessment of the perceived general exertion in a continuous dynamic physical exercise test. The sample was composed of 20 healthy male university students, with ages ranging from 18 to 29, sedentary and presenting compatible spirometric values with normality (Brazilian Consensus on Ergometry). The subjects filled out the protocol of the ramp continuous dynamic physical exercise test (RCDPET) using an electrically braked cycle ergometer at a pace of 60 rpm, with the application of the psychophysical scales. The frequency of the effort during the exercise was induced through the increase of the complexity and the resistance, using the test already mentioned. For the data analysis psychophysics analysis and parametric statistics were used, through the Pearson correlation, linear regression and Student-t test. A clear linear correlation was found between the scales (r=0,97, p<0,05), the scales and oxygen uptake (CR10: r=0,90; VAS: r=0,90) and heart rate values (CR10: r=0,89; VAS: r=0,91). Precise assessment were also found irrespective from the scale used (n=0,99; r2=0,99). These results suggest that the physical magnitudes of VAS and Borg´s CR10 scales are highly correlated. Moreover, in both scales, the increase of the power, the heart rate and the oxygen uptaken corresponds to the increase of the subjective estimations of the participants in relation to the physical effort. These may indicate a clear interaction between the different variable present during the continuous dynamic physical exercise test.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Dissertacao.pdf (819.64 Kbytes)
Fecha de Publicación
2007-02-26
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.