Doctoral Thesis
DOI
https://doi.org/10.11606/T.58.2012.tde-23052012-150900
Document
Author
Full name
Rodrigo Teixeira Macri
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2012
Supervisor
Committee
Matsumoto, Mirian Aiko Nakane (President)
Borsatto, Maria Cristina
Romano, Fábio Lourenço
Sakima, Mauricio Tatsuei
Sinhoreti, Mário Alexandre Coelho
Title in Portuguese
Laser de CO2 como auxiliar na remoção de bráquetes estéticos cerâmicos
Keywords in Portuguese
braquetes ortodônticos cerâmicos
Descolagem
lasers de CO2
Abstract in Portuguese
Este estudo avaliou a eficiência do uso do laser de CO2 com comprimento de onda de 10,6 m como auxiliar na remoção de bráquetes estéticos cerâmicos. Para este estudo foram utilizados 105 pré-molares inferiores humanos recentemente extraídos, que receberam irradiações com laser de CO2 antes da descolagem dos bráquetes. Na primeira fase deste estudo, o objetivo foi mensurar e comparar a temperatura no compósito de colagem do bráquete e na câmara pulpar após aplicação do laser de CO2 , para observar a segurança para o esmalte, bem como se a temperatura era suficiente para fragilizar o compósito, facilitando a remoção do bráquete. Nesta etapa foram utilizados 30 pré-molares inferiores recentemente extraídos, sendo que cada um recebeu 4 irradiações com diferentes protocolos de maneira aleatória. Foram testados 12 diferentes protocolos variando o tempo de irradiação (3 e 5s), a duração do pulso (0,01 e 0,03s) e a potência (5, 8 e 10W). Cada protocolo foi utilizado por 10 vezes (n=10), totalizando 120 irradiações. Em todas as irradiações os corpos-de-prova foram imersos em banho térmico com água a 37º C. Foram encontrados 4 protocolos cuja variação da temperatura na polpa foi menor que 5,5º C, portanto compatível com a saúde da polpa. Na segunda etapa do estudo, o objetivo foi avaliar a resistência ao cisalhamento após a aplicação do laser utilizando os protocolos cuja temperatura na polpa não fosse superior a 5,5º C. Setenta e cinco pré-molares inferiores humanos foram divididos em 5 grupos, dos quais um não foi submetido à irradiação, sendo considerado Controle (C). Nos 4 grupos restantes, irradiações foram realizadas como descrito a seguir: Grupo I (potência 5W; tempo de pulso 0,01s; tempo de aplicação 3s), Grupo II (5W; 0,03s e 3s), Grupo III (8W; 0,01s e 3s) e Grupo IV (10W; 0,01s e 3s). Cada grupo foi formado por 15 corpos-de-prova (n=15). Após a descolagem do bráquete foi avaliado o Índice de Remanescente Adesivo (IRA). Após as mensurações e aplicação da Análise de Variância (ANOVA) e do teste de Tukey foi constatado que o único grupo que apresentou diminuição na força de remoção foi o IV (7,33 MPa) em relação ao grupo C (10,81 MPa) sendo assim considerado seguro e eficaz na diminuição da resistência do compósito.
Title in English
CO2 laser-assisted debonding for esthetic ceramic brackets
Keywords in English
ceramic orthodontic brackets
CO2 laser
debonding
Abstract in English
This study evaluates the efficacy CO2 10,6 m laser-assisted debonding esthetic ceramic brackets. For this purpose it was used 105 recently extracted lower human premolars that were irradiated with CO2 laser before debonding. In the first phase, the objectives were to measure and compare the temperature in composite for bracket bonding and at the pulp chamber after CO2 laser irradiation, to observe the safety for enamel, as well the temperature was enough to softening the composite, making debonding bracket easier. In this part it was used 30 lower premolar recently extracted, and each one received 4 irradiations with different protocols, randomly choose. It was tested 12 different protocols varying time of irradiation (3 and 5s), pulse duration (0,01s e 0,03s) and power (5, 8 and 10W). Each protocol was repeated for 10 times (n=10), resulting 120 irradiations. In every irradiation the teeth tested were immerse in warm water bath at 37o C. It was found 4 protocols with pulp temperature lower than 5,5º C, so this is compatible with pulp health. In the second phase of this study, the objective was to evaluate the shear bond strength after laser irradiation, using the protocols with pulp chamber temperatures lower than 5,5º C. Seventy-five lower human premolars was shared in 5 groups. One group did not receive laser irradiation and considered Control (C) and the other groups the irradiation was made as it follows: Group I (power density 5W; pulse duration 0,01s; irradiation time 3s), Group II (5W; 0,03s, 3s), Group III (8W; 0,01s; 3s) and Group IV (10W; 0,01s; 3s). After results ANOVA and Tukey tests were made. Group IV presented lowering in SBS force (7,33 MPa) when compared with C (10,81MPa). This protocol was founded as a safe and efficient in softening composite layer.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2012-09-25
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.