• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.58.2019.tde-31072018-093655
Documento
Autor
Nombre completo
Alvaro Augusto Junqueira Júnior
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
Ribeirão Preto, 2018
Director
Tribunal
Silva, Marco Antonio Moreira Rodrigues da (Presidente)
Bataglion, Cesar
Felicio, Claudia Maria de
Leoni, Graziela Bianchi
Minto, André Marcelo Peruchi
Título en portugués
Avaliação da acurácia de imagens tridimensionais realizadas em sistema de estereofotogrametria portátil
Palabras clave en portugués
Antropometria
Estereofotogrametria
Face
Resumen en portugués
A configuração e o formato das estruturas craniofaciais, a oclusão dentária, a musculatura orofacial bem como a harmonia facial são determinantes para as características próprias da face humana. Instrumentos manuais como paquímetro e fitas métricas têm sido tradicionalmente utilizados para realizar as medidas antropométricas, diretamente de um sujeito em ambiente clínico. O avanço tecnológico possibilitou transformar a aquisição destas medidas analógicas em medições digitais, tornando possível aquisições rápidas, precisas e sem radiação. Tais informações podem, ainda, ser arquivadas para futuras análises e compartilhamento de informações com colegas e pacientes. A estereofotogrametria tem se destacado dentre as novas técnicas de captação de imagens tridimensionais, onde um grupo de câmeras de rápida captura fotografam a imagem do indivíduo a partir de variadas angulações. Atualmente, sistemas portáteis de estereofotogrametria vêm sendo propostos no mercado por apresentarem maior praticidade e simplicidade no manuseio. A proposta do presente estudo foi avaliar a precisão e a reprodutibilidade de um sistema de estereofotogrametria 3D portátil (Vectra H1, Canfield Scientific, Fairfield, NJ, EUA) em medições dos tecidos moles faciais de 30 participantes e de um cubo de medidas definidas, comparando tais medidas com as obtidas por um sistema de estereofotogrametria 3D fixo (Vectra M3, Canfield Scientific, Fairfield, NJ, EUA), de precisão e reprodutibilidade estabelecidas e validadas, através de análise quantitativa dos possíveis erros. Foram realizadas marcações craniométricas transitórias em tecido mole da face nos 30 participantes do estudo (n=30), sendo estes submetidos à aquisição de imagens pela técnica da estereofotogrametria, tanto pelo sistema fixo Vectra M3, quanto pelo sistema portátil Vectra H1. Trinta pontos de referência (landmarks) foram utilizados para realizar as medidas (em mm) de 34 distâncias. Quanto ao cubo, foram avaliados, no total, 20 ângulos, 20 áreas e 9 distâncias lineares. Os resultados obtidos pela metodologia estabelecida, juntamente com a correlação aos achados da literatura, permitiram concluir que o sistema portátil Vectra H1 apresentou precisão e repetibilidade comparáveis com o sistema fixo Vectra M3, evidenciando sua capacidade de capturar imagens tridimensionais de modo eficaz, o que torna viável seu uso nas mais diversas aplicações clínicas
Título en inglés
Accuracy evaluation of tridimensional images performed by portable stereophotogrammetric system
Palabras clave en inglés
Anthropometry
Face
Stereophotogrammetry
Resumen en inglés
The human face presents characteristics according to dental occlusion, facial harmony, orofacial musculature, besides the format and configuration of craniofacial structures. Traditionally, anthropometric measurements have been acquired through direct measurements of a subject inside clinical environment, using calipers and metric tapes to measure distance between arches and landmarks. Along with scientific breakthrough, the data, used to be analogic, became digital. It opened the possibility of quick, precise and radiation-free acquisitions, with its details being simultaneously archived for future analysis and being able to be easily shared with patients and colleagues. Among new facial analysis methods the stereophotogrammetry technique has emerged, where a group of cameras with fast acquisition take photographs of the subject from multiple angles. Nowadays, portable stereophotogrammetric are being proposed, as they are more practical and easy to use. The aim of this work was analyze the accuracy and reproducibility of a portable 3D stereophotogrammetric system (Vectra H1, Candield, Fairfeld, NJ, USA) in measurements of facial soft tissue of 30 participants and defined measures of a cube, comparing these measurements with those obtained by a set 3D stereophotogrammetric system (Vectra M3, Candield, Fairfeld, NJ, USA), which has it's accuracy and reproducibility previously validated, through quantitative analysis of possible errors. Thirty temporary landmarks were used to make the measurements (in mm) of 34 distances in 30 participants (n=30). Regarding the cube, 20 angles, 20 areas and 9 linear distances were evaluated. The obtained results by the established methodology, along with the correlation to literature findings, allowed us to conclude that the Vectra H1 portable system has shown accuracy and reproducibility as good as the Vectra M3 set system, evidencing it's capability to reliably capture tridimensional images, what makes practicable it's use in the most diverse clinical applications
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2019-07-23
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.