• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.58.2017.tde-16032016-141938
Document
Auteur
Nom complet
Rafaella Mariana Fontes de Bragança
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
Ribeirão Preto, 2015
Directeur
Jury
Mazzetto, Marcelo Oliveira (Président)
Bataglion, Cesar
Prado, Celio Jesus do
Souza, Valéria Oliveira Pagnano de
Titre en portugais
Estudo da repetibilidade de manobras para o registro da relação cêntrica após a aplicação da ULF-TENS, por meio da Análise Eletrônica de Posição (EPA)
Mots-clés en portugais
Côndilo da mandíbula
Estimulação elétrica nervosa transcutânea
Oclusão dentária
Registro da relação maxilomandibular
Resumé en portugais
A relação cêntrica (RC) é uma posição de grande importância no diagnóstico e tratamento em diversas áreas odontológicas. Durante a manipulação em RC, é importante impedir que a memória neuromuscular conduza a um registro incorreto. A neuroestimulação elétrica transcutânea de ultra baixa frequência (ULF-TENS) reduz a atividade eletromiográfica de músculos da mastigação. Desta forma, o presente estudo avaliou a influência da ULF-TENS no deslocamento da cabeça da mandíbula e na repetibilidade das técnicas de manipulação em RC (Bimanual de Dawson, tiras de Long e sistema R.O.C.A), além de verificar qual destas técnicas apresenta maior variabilidade. Para isso, 25 participantes sem Disfunção Temporomandibular (DTM) foram submetidos à duas etapas do estudo realizadas por meio da análise eletrônica de posição (EPA), que permite a avaliação da posição condilar em três eixos (X, Y e Z). Na primeira (ST), foram feitas três sequências com três registros de RC cada, um por técnica de manipulação. Na segunda (CT), foi aplicada a ULF-TENS por 30 minutos antes das sequências de registros, também realizada por três vezes. Utilizou-se o Mann-Whitney (p ≤ 0,05) para verificar a influência da ULF-TENS no deslocamento total para as técnicas Bimanual de Dawson, tiras de Long e sistema R.O.C.A e o ICC e 1-tailed F test a fim de avaliar a repetibilidade e a variância, respectivamente, dessas técnicas. A utilização da ULF-TENS não influenciou no deslocamento total da cabeça da mandíbula, independentemente da técnica de registro de RC utilizada (p>0,05). Apenas a técnica Bimanual apresentou uma melhora na repetibilidade com o uso da ULF-TENS, que foi restrita aos eixos X e Y direitos. Na comparação da variância entre as técnicas, a Bimanual demonstrou menor variação no eixo X, a de Long e R.O.C.A variaram menos no eixo Y e a de Long novamente teve menor variação no eixo Z. Pode-se concluir que o uso da ULF-TENS não altera o posicionamento condilar e melhora, embora discretamente, a repetibilidade apenas da técnica Bimanual. No geral, a técnica de Long apresentou menor variabilidade entre os participantes.
Titre en anglais
Study of the repeatability of centric relation registration techniques after the application of ULF-TENS by means of Electronic Position Analysis (EPA)
Mots-clés en anglais
Dental occlusion
Jaw relation record
Mandibular condyle
Transcutaneous electric nerve stimulation
Resumé en anglais
Centric relation (CR) is a position of great importance in diagnosis and treatment for several dental specialties. When guiding the jaw to CR, it is important to prevent the neuromuscular memory to mislead the record. Ultra low frequency-transcutaneous electrical nerve stimulation (ULF-TENS) reduces the electromyographic activity of masticatory muscles. Thus, the current study evaluated the influence of ULF-TENS in the displacement of the mandibular condyle and in the repeatability of centric relation registration techniques (Bimanual manipulation, Long technique, R.O.C.A. wires). In addition it was verified which of these techniques presents greater variability. For this purpose, 25 participants without Temporomandibular disorder (TMD) underwent two study stages conducted via electronic position analysis (EPA), which allows the evaluation of condylar position in three axes (X, Y e Z). In the first stage (NT), three sequences were made with three CR records each, one for manipulation technique. In the second stage (WT), the ULF-TENS was applied for 30 minutes before the record sequences, also performed for three times. Mann-Whitney test (p ≤ 0.05) was used to check the ULF-TENS influence on total displacement for Bimanual manipulation, Long technique and R.O.C.A. wires. ICC and 1-tailed F test were applied to assess the repeatability and variance, respectively, of these same techniques. Application of ULF-TENS did not influence the condyle total displacement, regardless of RC recording technique used (p> 0.05). Only Bimanual technique showed an improvement in repeatability with the use of ULF-TENS, which was restricted to the X and Y right axes. Concerning the variance comparison between the techniques, Bimanual manipulation showed less variation in the X axis, Long technique and R.O.C.A. wires varied less in the Y axis and Long technique was again less variable in the Z axis. It could be concluded that the use of ULF-TENS does not affect the condylar positioning and improved, although slightly, only the repeatability of Bimanual manipulation. Overall, Long technique presented lower variability among participants.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2017-08-11
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.