• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.58.2019.tde-04102022-115049
Documento
Autor
Nome completo
Barbara Braga Jobim
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
Ribeirão Preto, 2019
Orientador
Banca examinadora
Cruz Filho, Antonio Miranda da (Presidente)
Correr Sobrinho, Lourenço
Rached Junior, Fuad Jacob Abi
Sousa Neto, Manoel Damião de
Título em português
Efeito do tempo de armazenamento sobre as propriedades físico-químicas do cimento endodôntico AH Plus
Palavras-chave em português
Cimento endodôntico
Endodontia
Propriedades físico-químicas
Resumo em português
O objetivo do presente estudo foi avaliar o efeito do tempo de armazenamento sobre as propriedades físico-químicas do cimento endodôntico AH Plus. Avaliou-se ainda, por meio de testes complementares, os elementos químicos presentes na amostra referente ao primeiro uso da pasta B. Os testes de escoamento e tempo de endurecimento foram conduzidos em conformidade com as Especificações nº 57 da ANSI/ADA. Os testes de solubilidade e alteração dimensional seguiram as modificações propostas por Carvalho-Júnior et al. (2007). Foram utilizados quatro caixas de cimento (C1, C2, C3 e C4), com as quais realizaram-se a aleatorização, para que todos os cimentos fossem utilizados em todos os testes até o final do experimento. Analisaram-se as propriedades de tempo de endurecimento, escoamento, solubilidade e alteração dimensional, em quatro momentos: logo que aberto (T0), após 30 (T30), 90 (T90) e 360 (T360) dias após a abertura. Os dados foram analisados por meio dos testes ANOVA one-way e Tukey (α=0,05). A média do tempo de endurecimento foi de 515,10 ± 54,89 minutos. No entanto, T0 ultrapassou os 10% estabelecidos como variação máxima pela ANSI/ADA (596,80 ± 7,05). T0 foi estatisticamente diferente (p≤0,01) de T30, T90 e T360. A propriedade de escoamento atendeu às normas ANSI/ADA (≥20 mm). Esta propriedade diminui significativamente (p≤0,05) com o passar do tempo. A solubilidade não excedeu 3% de massa no período de análise. A expansão do cimento (0,94%±0,12), apesar de ter diminuído com o tempo, não atendeu às especificações da ANSI/ADA. Na amostra inicial da pasta B, foram detectados todos os componentes dessa pasta com predominância de óleo de silicone. Com exceção da alteração dimensional, as propriedades do cimento AH Plus aqui avaliadas não sofrem alterações no período de 360 dias de armazenamento.
Título em inglês
Effect of storage time on the physico-chemical properties of endodontic sealer AH Plus
Palavras-chave em inglês
Endodontic cement
Endodontics
Physicochemical properties
Resumo em inglês
The aim of the present study was to evaluate the effect of storage time on the physico-chemical properties of endodontic sealer AH Plus. The chemical elements present in the first part of paste B were further evaluated by complementary tests. Flow and setting time tests were conducted in accordance with ANSI/ADA Specifications No 57. Solubility and dimensional change tests followed the modifications proposed by Carvalho-Júnior et al. (2007). Four sealers boxes were used (C1, C2, C3 and C4), which randomization was performed so that all sealers were used in all tests until the end of the experiment. The properties of setting time, flow, solubility and dimensional change were analyzed at four moments: once it was opened (T0) after 30 days of open (T30), after 90 days of open (T90) and after 360 days (T360). Data were analyzed by ANOVA one-way and Tukey tests (α=0,05). The average setting time was 515.10 ± 54.89 minutes. However, in T0, it exceeded the 10% established as maximum variation by ANSI / ADA (596.80 ± 7.05). T0 was statistically different (P≤0. 01) from T30, T90 and T360. The AH Plus flow complied with ANSI / ADA standards (≥20 mm). This property significantly decreased (P≤0.05) over time. Solubility did not exceed 3% of mass in the analysis period. Sealer expansion (0.94% ± 0.12), although decreasing over time, did not met ANSI / ADA specifications. In the initial sample of paste B, all components of this paste were present, but the predominance of silicone oil were detected. With the exception of dimensional change, the evaluated properties of AH Plus do not change during the 360 days of storage.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2022-10-05
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.